Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
Note: You are viewing specs for the original DELTA (Gen 1)
This legacy model has been officially replaced by a newer version with improved specs.
Yes - DELTA (Gen 1) has enough running and surge power for the Starlink System. Target ~115W running / 115W surge; the generator provides 1800W / 3300W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
115W required -> 1,800W available (1,685W headroom)
Startup peak with safety buffer applied.
115W required -> 3,300W available (3,185W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 8.8h
Device profile reference: up to 24h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Starlink Standard (100W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Starlink Standard | 100W | 100W | Safe | ~8.8h | OEM Manual |
Show expert analysisTechnical: **Running load:** 100 W. **Surge:** 100 W. **Voltage:** 120 V AC. No surge headroom required since startup and steady-state loads are identical. Field note: Starlink AC adapter draws full load continuously. Confirm power station AC inverter can sustain 100 W for the intended runtime without thermal cutoff. Can I run Starlink Standard off-grid continuously? Only if your power source can supply at least 100W continuous and 100W surge at 120V. | |||||
| Starlink Standard Actuated | 75W | 75W | Safe | ~11.8h | OEM Manual |
Show expert analysisTechnical: **Running load:** 75 W continuous. **Surge:** 75 W (no inrush). **Voltage:** 120 V AC required. Flat power profile, no motor or compressor. Field note: Check your power station's AC outlet rated continuous output. Some units derate below 100 W sustained load. Can I run this on a 500 Wh power station for a full day? Only if your power source can supply at least 75W continuous and 75W surge at 120V. It depends on total capacity and inverter efficiency. 1800 Wh daily demand exceeds a 500 Wh battery, requiring solar input or recharging mid-cycle. | |||||
| Starlink Mini | 40W | 40W | Safe | ~22.1h | OEM Manual |
Show expert analysisTechnical: **Running load:** 40 W, **surge:** 40 W, **voltage:** 120 V AC. No inrush spike. Constant resistive draw throughout operation. Field note: Starlink Mini ships with a USB-C power supply. Verify AC adapter spec if using inverter output instead of native DC from power station. Can I run Starlink Mini on a portable power station continuously? Only if your power source can supply at least 40W continuous and 40W surge at 120V. | |||||
This unit ranks #16 of 33 compatible generators for this device by buffered margin (Overkill class).
33 of 33 generators are SAFE+TIGHT for Starlink System.
Fit class uses buffered needs (running and surge) for this device.
Off-Grid Internet
Select Your Model:
Free Tools
The 3300W surge capacity can handle typical startup demands from refrigerators, well pumps, and other motor-driven appliances that require brief inrush current. The 1800W continuous rating supports sustained loads like power tools, kitchen appliances, and electronics. Understand that this is a legacy unit no longer in active production.
This legacy model uses NMC lithium chemistry in a 1260Wh battery pack. The manufacturer documentation outlines operational guidelines and user precautions for safe charging and discharging cycles. Source: EcoFlow DELTA 1300 User Manual (manufacturer documentation). This model has been discontinued and replaced by newer generations.
Keep your Starlink System running with solar โข MPPT: 10โ 65V โข Max: 400W
Official 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 350W Panel
Adapter required: MC4 -> XT60.
Smart Value 200W Panel
Adapter required: MC4 -> XT60.
Yes. The EcoFlow DELTA (Gen 1) provides 1800W running / 3300W surge. The Starlink System needs 115W / 115W (including 15% buffer). That leaves 1685W of running headroom and 3185W of surge margin.
Approximately 8.8 hours, based on the Starlink System's 100W draw and the DELTA (Gen 1)'s 1260Wh capacity (70% usable after real-world losses).
With 420W allocated to the Starlink System, the DELTA (Gen 1) still has ~920W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your DELTA (Gen 1), keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Starlink System
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Starlink Standard (100W). Surge worst case = Starlink Standard (100W).
EcoFlow DELTA 1300 User Manual (V1.0)
Similar-output alternatives you can compare side by side.