Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
Yes - DELTA 3 Plus has enough running and surge power for the Starlink System. Target ~115W running / 115W surge; the generator provides 1800W / 3600W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
115W required -> 1,800W available (1,685W headroom)
Startup peak with safety buffer applied.
115W required -> 3,600W available (3,485W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 7.2h
Device profile reference: up to 24h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Starlink Standard (100W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Starlink Standard | 100W | 100W | Safe | ~7.2h | OEM Manual |
Show expert analysisTechnical: **Running load:** 100 W. **Surge:** 100 W. **Voltage:** 120 V AC. No surge headroom required since startup and steady-state loads are identical. Field note: Starlink AC adapter draws full load continuously. Confirm power station AC inverter can sustain 100 W for the intended runtime without thermal cutoff. Can I run Starlink Standard off-grid continuously? Only if your power source can supply at least 100W continuous and 100W surge at 120V. | |||||
| Starlink Standard Actuated | 75W | 75W | Safe | ~9.6h | OEM Manual |
Show expert analysisTechnical: **Running load:** 75 W continuous. **Surge:** 75 W (no inrush). **Voltage:** 120 V AC required. Flat power profile, no motor or compressor. Field note: Check your power station's AC outlet rated continuous output. Some units derate below 100 W sustained load. Can I run this on a 500 Wh power station for a full day? Only if your power source can supply at least 75W continuous and 75W surge at 120V. It depends on total capacity and inverter efficiency. 1800 Wh daily demand exceeds a 500 Wh battery, requiring solar input or recharging mid-cycle. | |||||
| Starlink Mini | 40W | 40W | Safe | ~17.9h | OEM Manual |
Show expert analysisTechnical: **Running load:** 40 W, **surge:** 40 W, **voltage:** 120 V AC. No inrush spike. Constant resistive draw throughout operation. Field note: Starlink Mini ships with a USB-C power supply. Verify AC adapter spec if using inverter output instead of native DC from power station. Can I run Starlink Mini on a portable power station continuously? Only if your power source can supply at least 40W continuous and 40W surge at 120V. | |||||
This unit ranks #17 of 33 compatible generators for this device by buffered margin (Overkill class).
33 of 33 generators are SAFE+TIGHT for Starlink System.
Fit class uses buffered needs (running and surge) for this device.
Off-Grid Internet
Select Your Model:
Free Tools
The 3600W surge capacity can support typical residential motor startup scenarios including refrigerator compressors, well pumps, and power tools with inductive loads. The 1024Wh capacity sustains the 1800W continuous rating for approximately 34 minutes at full draw. This configuration can handle brief high-demand events common in backup power and job site applications.
LFP chemistry provides stable electrochemical performance under load cycling. The 3600W surge rating indicates transient overcurrent capability designed for inductive startup events. Source: EcoFlow DELTA 3 Plus User Manual v1.0 (Output Specs Section) (manufacturer documentation). Users must verify that connected equipment falls within these published limits.
Keep your Starlink System running with solar โข MPPT: 11โ 60V โข Max: 1000W
Official 400W Panel
Adapter required: MC4 -> XT60i.
Smart Value 350W Panel
Adapter required: MC4 -> XT60i.
Smart Value 200W Panel
Adapter required: MC4 -> XT60i.
Yes. The EcoFlow DELTA 3 Plus provides 1800W running / 3600W surge. The Starlink System needs 115W / 115W (including 15% buffer). That leaves 1685W of running headroom and 3485W of surge margin.
Approximately 7.2 hours, based on the Starlink System's 100W draw and the DELTA 3 Plus's 1024Wh capacity (70% usable after real-world losses).
With 440W allocated to the Starlink System, the DELTA 3 Plus still has ~900W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your DELTA 3 Plus, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Starlink System
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Starlink Standard (100W). Surge worst case = Starlink Standard (100W).
EcoFlow DELTA 3 Plus User Manual
Similar-output alternatives you can compare side by side.