Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V/240V available
Yes - DELTA Pro 3 has enough running and surge power for the Electric Stove (Single Burner). Target ~1981W running / 1981W surge; the generator provides 4000W / 8000W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V/240V available
Continuous draw with safety buffer applied.
1,981W required -> 4,000W available (2,019W headroom)
Startup peak with safety buffer applied.
1,981W required -> 8,000W available (6,019W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 1.6h
Device profile reference: up to 1h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Duxtop Portable Induction Cooktop (1800W) (1,800W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Duxtop Portable Induction Cooktop (1800W) | 1,800W | 1,800W | Safe | ~1.6h | OEM Manual |
Show expert analysisTechnical: **Running load:** 1800 W. **Surge:** 1800 W (resistive heating element, no inrush spike). **Voltage:** 120 V AC required. Power station must sustain 1800 W continuous output on AC inverter. Field note: Verify power station inverter rating is at least 2000 W continuous to allow headroom. Resistive load provides stable draw without cyclic spikes. Can I run this induction cooktop on a 1500 W power station? Only if your power source can supply at least 1800W continuous and 1800W surge at 120V. | |||||
| Cuisinart CB-30 Cast-Iron Single Burner | 1,300W | 1,300W | Safe | ~2.2h | OEM Manual |
Show expert analysisTechnical: **Running load:** 1300 W at 120V. **Surge:** 1300 W (resistive heating element, no motor startup). Requires power station with continuous 1300 W rating and 120V AC outlet. Field note: Verify power station continuous output meets or exceeds 1300 W. Insufficient headroom will trigger overload shutdown during cooking. Can I use this burner with a 1000W power station? Only if your power source can supply at least 1300W continuous and 1300W surge at 120V. | |||||
| Ovente BGC101S Single Electric Burner | 1,000W | 1,000W | Safe | ~2.9h | OEM Manual |
Show expert analysisTechnical: **Running load:** 1000 W. **Surge:** 1000 W. **Voltage:** 120 V AC. Resistive heating element draws steady current with no inrush spike. Power station must supply clean 120 V output and sustain 1000 W continuous. Field note: Verify power station AC outlet delivers rated continuous output. Undersized inverters will overheat or shut down under sustained resistive load. Can I use this burner with a 500 Wh portable power station? Only if your power source can supply at least 1000W continuous and 1000W surge at 120V. Runtime would be approximately 30 minutes before depletion, provided inverter does not thermally limit first. | |||||
This unit ranks #18 of 21 compatible generators for this device by buffered margin (Overkill class).
21 of 33 generators are SAFE+TIGHT for Electric Stove (Single Burner).
Fit class uses buffered needs (running and surge) for this device.
Portable Cooking
Select Your Model:
This load may exceed a standard 15A outlet. Verify your station has a higher-amperage outlet (20A/30A) before purchase.
Free Tools
The 8000W surge rating can support typical compressor startup in residential air conditioners, well pumps, and refrigeration equipment. Most single-phase motor loads under 2HP can start on this surge budget. The 4000W continuous capacity can handle simultaneous operation of multiple circuits including HVAC blowers, lighting, and standard appliances during extended outages.
This unit provides 4096Wh of LFP battery capacity with 4000W continuous and 8000W surge output capability. Source: EcoFlow DELTA Pro 3 User Manual v1.1 (AC Output Specifications) (manufacturer documentation). The LFP chemistry offers thermal stability compared to older lithium-ion chemistries, though all battery systems require proper ventilation and adherence to installation guidelines.
Keep your Electric Stove (Single Burner) running with solar โข MPPT: 30โ 150V โข Max: 2600W
Official 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 350W Panel
Adapter required: MC4 -> XT60.
Yes. The EcoFlow DELTA Pro 3 provides 4000W running / 8000W surge. The Electric Stove (Single Burner) needs 1981W / 1981W (including 10% buffer). That leaves 2019W of running headroom and 6019W of surge margin.
Approximately 1.6 hours, based on the Electric Stove (Single Burner)'s 1800W draw and the DELTA Pro 3's 4096Wh capacity (70% usable after real-world losses).
With 1320W allocated to the Electric Stove (Single Burner), the DELTA Pro 3 still has ~80W of margin. These devices could run simultaneously:
Efficiency Hack: Large appliances like the Electric Stove (Single Burner) cycle on and off. To maximize the 1.6 hours of runtime, try to minimize how often you open the device or introduce heat loads.
Compare all 33 generators for the Electric Stove (Single Burner)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Duxtop Portable Induction Cooktop 1800W (1800W). Surge = running (resistive heating element โ no motor inrush).
EcoFlow DELTA Pro 3 User Manual v1.1 (AC Output Specifications)
Similar-output alternatives you can compare side by side.