Voltage Gate
PASSDevice output type must match generator output.
240V required -> 120V/240V available
3 of 3 models are compatible with this generator.
Jump to model-specific results โSame decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
240V required -> 120V/240V available
Continuous draw with safety buffer applied.
4,950W to 6,051W required -> 6,000W available (1,050W headroom on lighter models)
Startup peak with safety buffer applied.
4,950W to 6,051W required -> 12,000W available (5,949W to 7,050W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 0.8h
Device profile reference: up to 3h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: State ProLine ESX-50-DOLS-120 (5,500W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| A. O. Smith ProLine ENS-50-110 | 4,500W | 4,500W | Safe | ~1.0h | OEM Verified |
Show expert analysisTechnical: **Running load:** 4500 W. **Surge:** 4500 W. **Voltage:** 240V split-phase required. Resistive heating element draws steady current without inrush spike. Field note: Ensure power station maintains 240V regulation under sustained 4500 W load. Voltage sag below 220V may trigger thermal cutoff. Can I power this water heater with a portable power station? Only if your power source provides 240V split-phase output and can supply 4500W continuous and 4500W surge. | |||||
| State ProLine ESX-50-DOLS-120 | 5,500W | 5,500W | Tight | ~0.8h | OEM Verified |
Show expert analysisTechnical: **Running load:** 5,500 W. **Surge:** 5,500 W. **Voltage:** 240V. Requires a power station with split-phase 240V output and sustained 5,500 W capacity. Field note: Confirm your power station supports continuous 5,500 W output without thermal derating. Verify 240V split-phase before connection. Can I run this water heater on a portable power station? Only if your power source provides 240V split-phase output and can supply 5500W continuous and 5500W surge. Verify voltage and sustained wattage capacity before attempting operation. | |||||
| State ProLine Master EN8-50-DORS-SG110 | 4,500W | 4,500W | Safe | ~1.0h | OEM Verified |
Show expert analysisTechnical: **Running load:** 4500 W continuous at 240V. **Surge:** 4500 W (resistive heating element, no inrush spike). Only compatible if your power station supplies true 240V split-phase output and sustained 4500 W capacity. Field note: Verify your power station explicitly supports 240V loads before connecting. Most portable units output 120V only and cannot safely power this water heater. Can I run this water heater on a portable power station? Only if your power source provides 240V split-phase output and can supply 4500W continuous and 4500W surge. Most consumer units do not. | |||||
This unit ranks #2 of 3 compatible generators for this device by buffered margin (Balanced class).
3 of 33 generators are SAFE+TIGHT for Electric Water Heater (50 Gal).
Fit class uses buffered needs (running and surge) for this device.
Hot Water Supply
Select Your Model:
This device typically needs 240V split-phase or a hardwired connection. Most portable stations are 120V-only. Verify the plug type and voltage on the device label/manual before purchase.
Free Tools
With 12000 watts of surge capacity, this system can handle typical startup loads for central air compressors, well pumps, and other motor-driven equipment common in residential settings. The 6000-watt continuous rating supports sustained operation of multiple high-draw appliances simultaneously. The 6144 Wh capacity provides meaningful runtime for essential circuits during grid outages.
This unit uses lithium iron phosphate (LFP) chemistry, known for stable thermal behavior in stationary storage applications. The system is designed with internal protections typical of grid-tied and off-grid battery platforms. Source: EcoFlow DELTA Pro Ultra User Manual (manufacturer documentation).
Keep your Electric Water Heater (50 Gal) running with solar โข MPPT: 80โ 450V โข Max: 5600W
Official 400W Panel
Smart Value 400W Panel
Smart Value 350W Panel
It depends on the model. 3 of 3 Electric Water Heater (50 Gal) models are compatible with the EcoFlow Delta Pro Ultra. See the model-specific results table for exact verdicts per model.
It depends on the model. Compatible models run approximately 0.8โ1.0 hours on the Delta Pro Ultra. 0 of 3 models are not compatible. See the model-specific results for details.
Power Tip: To get the most out of your Delta Pro Ultra, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Electric Water Heater (50 Gal)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = State ProLine ESX-50-DOLS-120 (5500W). Surge = running (resistive heating element โ no motor inrush).