Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
This pairing clears the safety headroom. Required ~65W running and 120W surge; the Yeti Pro 4000 is rated 3600W / 7200W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
65W required -> 3,600W available (3,535W headroom)
Startup peak with safety buffer applied.
120W required -> 7,200W available (7,080W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 49.8h
Device profile reference: up to 8h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: ResMed AirSense 10 AutoSet (104W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| ResMed AirSense 11 AutoSet | 56.1W | 73.2W | Safe | ~49.8h | OEM Manual |
Show expert analysisTechnical: **Running load:** 56.1 W typical. **Surge:** 73.2 W peak. **Voltage:** 120 V AC. The machine draws continuous low power with minimal startup spike. Most portable power stations with 120V inverters and 100+ W output handle this load comfortably. Field note: Verify your power station provides stable 120V AC output and at least 75W continuous rating. Disable the heated humidifier to reduce draw by ~30% and extend runtime. Always carry a backup power source for life-critical equipment. Can I run the AirSense 11 on a 500Wh power station? Yes โ at 56.1W typical, a 500Wh station (350Wh usable) provides roughly 6 hours. Disabling the humidifier drops draw to ~40W and extends runtime to a full night. | |||||
| ResMed AirSense 10 AutoSet | 53W | 104W | Safe | ~52.7h | OEM Manual |
Show expert analysisTechnical: **Running load:** 53 W typical. **Surge:** 104 W peak. **Voltage:** 120 V AC required. The AirSense 10 has a higher peak draw than the newer AirSense 11 due to its older motor design. Field note: The 104W peak is the sizing constraint. Ensure your power station can handle at least 120W continuous to cover the startup surge with margin. Use a pure sine wave inverter โ modified sine wave may cause motor faults in medical devices. Can I use a portable power station rated for 100W continuous? Risky โ the AirSense 10 peaks at 104W. A station rated at exactly 100W may trip on startup. Look for 150W+ continuous rating to be safe. | |||||
| Fisher & Paykel SleepStyle Auto | 39W | 76W | Safe | ~71.7h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 39 W typical. **Surge:** 76 W peak. **Voltage:** 120 V AC required. The SleepStyle has an integrated power supply (no external brick) and built-in heated humidifier. The 39W figure includes the humidifier at typical settings. Field note: The SleepStyle is the most power-efficient full-size CPAP here. At 39W typical, even a compact 500Wh power station covers a full night with margin. The integrated humidifier means no separate heater to add to the load. Is the Fisher & Paykel SleepStyle easier to run off-grid than ResMed? Yes โ at 39W typical vs 53-56W for ResMed models, the SleepStyle draws roughly 30% less power. An 8-hour night consumes ~312 Wh vs 424-449 Wh for ResMed. | |||||
This unit ranks #29 of 33 compatible generators for this device by buffered margin (Overkill class).
33 of 33 generators are SAFE+TIGHT for CPAP Machine.
Fit class uses buffered needs (running and surge) for this device.
8-Hour Sleep Session
Select Your Model:
Free Tools
The 7200 W surge can handle typical compressor-based appliances like well pumps, refrigerators, and air conditioning startup events on 120V circuits. The 3600 W continuous rating supports sustained operation once inrush currents settle, making this unit a strong option for heavy 120V backup loads.
This unit uses LFP chemistry and draws from manufacturer documentation for its output specifications. The 7200 W surge rating reflects the inverter's transient capacity, not a thermal or safety certification. Source: Goal Zero Yeti Pro 4000 User Manual (Output Specifications) (manufacturer documentation).
Keep your CPAP Machine running with solar โข MPPT: 13.3โ 145V โข Max: 3000W
Official 200W Panel
Smart Value 400W Panel
Adapter required: MC4 -> HPP+.
Smart Value 400W Panel
Adapter required: MC4 -> HPP+.
Yes. The Goal Zero Yeti Pro 4000 provides 3600W running / 7200W surge. The CPAP Machine needs 65W / 120W (including 15% buffer). That leaves 3535W of running headroom and 7080W of surge margin.
Approximately 49.8 hours, based on the CPAP Machine's 56W draw and the Yeti Pro 4000's 3993.6Wh capacity (70% usable after real-world losses).
With 2460W allocated to the CPAP Machine, the Yeti Pro 4000 still has ~364W of margin. These devices could run simultaneously:
Pro Tip for Medical Users: According to energy reports, turning off the humidifier on your CPAP Machine can double your runtime. Using a DC cable instead of the AC plug is also recommended to avoid inverter inefficiency.
Compare all 33 generators for the CPAP Machine
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = ResMed AirSense 11 (56.1W typical). Surge worst case = ResMed AirSense 10 (104W peak).
Goal Zero Yeti PRO 4000 (120V) User Guide
Similar-output alternatives you can compare side by side.