Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
Yes - Yeti Pro 4000 has enough running and surge power for the Electric Blanket. Target ~199W running / 199W surge; the generator provides 3600W / 7200W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
199W required -> 3,600W available (3,401W headroom)
Startup peak with safety buffer applied.
199W required -> 7,200W available (7,001W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 15.5h
Device profile reference: up to 8h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
5 of 5 models are SAFE or TIGHT. Most demanding model: Biddeford Electric Warming Blanket (Full) (180W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Biddeford Electric Warming Blanket (Full) | 180W | 180W | Safe | ~15.5h | OEM Verified |
Show expert analysisTechnical: **Running load:** 180 W. **Surge:** 180 W (resistive heating element, no inrush). **Voltage:** 120 V AC. A power station with at least 200 W continuous AC output and 120 V support is the minimum threshold. Field note: Verify the power station AC outlet provides 120 V. Resistive loads tolerate most inverter waveforms, but confirm the station's continuous rating exceeds 180 W. Can I run this blanket overnight on battery power? Only if your power source can supply at least 180W continuous and 180W surge at 120V. It depends on the power station's usable capacity. An 8-hour session requires at least 1440 Wh, so only stations rated above that threshold (accounting for inverter losses) will complete the full cycle. | |||||
| Westinghouse Heated Throw (50x60) | 100W | 100W | Safe | ~28.0h | OEM Verified |
Show expert analysisTechnical: **Running load:** 100W. **Surge:** 100W (resistive heating element). Requires 120V AC output from the power station. No surge spike present, as heating coils draw constant current. Field note: Verify your power station's inverter can sustain 100W for the full duration. Cold ambient temperatures may reduce battery capacity by 10-20%. Can I run this heated throw all night on a 500Wh power station? Only if your power source can supply at least 100W continuous and 100W surge at 120V. Only if you limit use to roughly 4-5 hours, accounting for inverter losses and reduced cold-weather battery performance. | |||||
| Sunbeam Microplush Ultimate Grey Heated Blanket (Queen) | 110W | 110W | Safe | ~25.4h | OEM Verified |
Show expert analysisTechnical: **Running load:** 110 W. **Surge:** 110 W (resistive heating, no inrush). **Voltage:** 120 V AC required. Draws constant wattage during active heating cycles. Field note: Verify power station AC outlet delivers stable 120 V under continuous 110 W load. Low wattage allows extended runtime on modest battery capacities. Can I run this heated blanket overnight on a portable power station? Only if your power source can supply at least 110W continuous and 110W surge at 120V. It depends on the power station's usable capacity and AC output rating. | |||||
| Sunbeam Brushed Fleece Heated Throw (Greystone) | 110W | 110W | Safe | ~25.4h | OEM Verified |
Show expert analysisTechnical: **Running load:** 110W. **Surge:** 110W. Requires 120V AC. Resistive heating element draws steady current with no inrush spike. Field note: Verify power station maintains 120V output under resistive load. Allow 15% inverter headroom for thermal stability. Can I run this heated throw all night on a portable power station? Only if your power source can supply at least 110W continuous and 110W surge at 120V. | |||||
| Sunbeam 2-in-1 Reversible Heated & Cooling Mattress Pad (Queen) | 110W | 110W | Safe | ~25.4h | OEM Verified |
Show expert analysisTechnical: **Running load:** 110 W continuous. **Surge:** 110 W (resistive heating element, no inrush). **Voltage:** 120 V AC required. Power station must supply stable 120 V AC output and deliver at least 110 W continuously for the duration of use. Field note: Verify power station capacity exceeds 880 Wh if running the full night. Thermal mattress pads draw steady power until thermostat cycles. Can I run this mattress pad through the night on a portable power station? Only if your power source can supply at least 110W continuous and 110W surge at 120V. Runtime depends on actual capacity and inverter efficiency. | |||||
This unit ranks #29 of 33 compatible generators for this device by buffered margin (Overkill class).
33 of 33 generators are SAFE+TIGHT for Electric Blanket.
Fit class uses buffered needs (running and surge) for this device.
Cold Night Warmth
Select Your Model:
Free Tools
The 7200 W surge can handle typical compressor-based appliances like well pumps, refrigerators, and air conditioning startup events on 120V circuits. The 3600 W continuous rating supports sustained operation once inrush currents settle, making this unit a strong option for heavy 120V backup loads.
This unit uses LFP chemistry and draws from manufacturer documentation for its output specifications. The 7200 W surge rating reflects the inverter's transient capacity, not a thermal or safety certification. Source: Goal Zero Yeti Pro 4000 User Manual (Output Specifications) (manufacturer documentation).
Keep your Electric Blanket running with solar โข MPPT: 13.3โ 145V โข Max: 3000W
Official 200W Panel
Smart Value 400W Panel
Adapter required: MC4 -> HPP+.
Smart Value 400W Panel
Adapter required: MC4 -> HPP+.
Yes. The Goal Zero Yeti Pro 4000 provides 3600W running / 7200W surge. The Electric Blanket needs 199W / 199W (including 10% buffer). That leaves 3401W of running headroom and 7001W of surge margin.
Approximately 15.5 hours, based on the Electric Blanket's 180W draw and the Yeti Pro 4000's 3993.6Wh capacity (70% usable after real-world losses).
With 1040W allocated to the Electric Blanket, the Yeti Pro 4000 still has ~1660W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your Yeti Pro 4000, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Electric Blanket
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Biddeford Electric Warming Blanket (Full) (180W). Surge = running (resistive heating element โ no motor inrush).
Goal Zero Yeti PRO 4000 (120V) User Guide
Similar-output alternatives you can compare side by side.