Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
1 of 4 models are compatible with this generator.
Jump to model-specific results โSame decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
1,541W to 1,871W required -> 1,500W available (41W to 371W short)
Startup peak with safety buffer applied.
1,541W to 1,871W required -> 3,000W available (1,129W to 1,459W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 0.4h
Device profile reference: up to 0.3h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
1 of 4 models are SAFE or TIGHT. Most demanding model: Dyson Supersonic r Professional (1,700W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Dyson Supersonic Origin | 1,600W | 1,600W | Fail | โ | OEM Verified |
Show expert analysisTechnical: **Running load:** 1600 W. **Surge:** 1600 W. Requires 120V AC. No surge multiplier indicates resistive heating element. Generator must supply at least 1600 W continuous at 120V to operate safely. Field note: Verify generator can sustain 1600 W before connecting. Allow 20% headroom above rated load for stable operation during peak heat cycles. Will this work on a 2000W generator? Only if your power source can supply at least 1600W continuous and 1600W surge at 120V. Check manufacturer load charts for real-world capacity under resistive heating. | |||||
| Dyson Supersonic r Professional | 1,700W | 1,700W | Fail | โ | OEM Verified |
Show expert analysisTechnical: **Running load:** 1700 W. **Surge:** 1700 W (resistive heating element, no motor spike). Requires 120V AC supply. Generator must sustain 1700 W continuously without voltage sag during the 18-minute runtime window. Field note: Verify generator can deliver full rated wattage at 120V under load. Undersized units may experience voltage drop during simultaneous appliance operation, causing thermal cutoff. Can I run this hair dryer on a 2000W inverter generator? Only if your power source can supply at least 1700W continuous and 1700W surge at 120V. Inverter generators often derate at altitude or high ambient temperature. | |||||
| Shark FlexStyle HD400 (1400W) | 1,400W | 1,400W | Tight | ~0.5h | OEM Verified |
Show expert analysisTechnical: **Running load:** 1400 W. **Surge:** 1400 W. Requires 120V AC supply. Resistive heating element yields identical running and surge demand. Generator must sustain continuous 1400 W output without voltage sag. Field note: Verify generator nameplate capacity exceeds 1400 W continuous. Voltage droop under load may reduce heating performance or trigger thermal shutdown. Can I run this styling tool on a 1500W portable generator? Only if your power source can supply at least 1400W continuous and 1400W surge at 120V. Marginal headroom increases risk of voltage sag and premature shutoff. | |||||
| Shark FlexStyle HD400 (1600W) | 1,600W | 1,600W | Fail | โ | OEM Verified |
Show expert analysisTechnical: **Running load:** 1600 W. **Surge load:** 1600 W. Requires 120V AC. Generator must supply continuous 1600 W minimum with no margin. Resistive heating element shows minimal inrush current. Field note: Zero headroom exists at 1600 W generator capacity. Any voltage sag or shared load will cause dropout. Verify available AC output rating before connecting. Can I run this on a 1600W generator? Only if your power source can supply at least 1600W continuous and 1600W surge at 120V. Any headroom deficit or shared circuit will interrupt operation. | |||||
This unit is outside the compatible set; 21 of 33 generators pass SAFE/TIGHT for this device.
21 of 33 generators are SAFE+TIGHT for Professional Hair Dryer.
Fit class uses buffered needs (running and surge) for this device.
Morning Routine
Select Your Model:
Free Tools
This unit can handle typical compressor-based loads like refrigerators and window AC units where startup surge falls within the 3000W envelope. The 1070Wh capacity supports moderate runtime on continuous loads under 1500W. It can start most residential sump pumps and small well pumps where inrush demand does not exceed the rated surge threshold.
LFP chemistry provides a stable platform for managing high-current transients during motor startup events. The 3000W surge rating allows the unit to absorb brief inrush currents without shutdown, though users must verify compatibility with specific appliances. Source: Jackery Explorer 1000 v2 User Manual (Sept 2024) (manufacturer documentation).
Keep your Professional Hair Dryer running with solar โข MPPT: 16โ 60V โข Max: 400W
Official 200W Panel
Smart Value 200W Panel
Adapter required: MC4 -> DC8020.
Smart Value 200W Panel
Adapter required: MC4 -> DC8020.
It depends on the model. 1 of 4 Professional Hair Dryer models are compatible with the Jackery Explorer 1000 v2. See the model-specific results table for exact verdicts per model.
It depends on the model. Compatible models run approximately 0.5โ0.5 hours on the Explorer 1000 v2. 3 of 4 models are not compatible. See the model-specific results for details.
Power Tip: To get the most out of your Explorer 1000 v2, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Professional Hair Dryer
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Dyson Supersonic r Professional (1700W). Surge = running (resistive heating element โ no motor inrush).
Jackery Explorer 1000 v2 User Manual (Sept 2024)
Similar-output alternatives you can compare side by side.