Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
It should run, but the margin is tight. Device spec is 1500W / 1500W and the generator is 1500W / 3000W. For safer headroom, target ~1651W / 1651W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
1,651W required -> 1,500W available (151W short)
Startup peak with safety buffer applied.
1,651W required -> 3,000W available (1,349W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 0.5h
Typical cycling estimate (65% duty): 0.8h
Device profile reference: up to 4h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Lasko CT16450 (Ceramic Tower) (1,500W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Lasko CT16450 (Ceramic Tower) | 1,500W | 1,500W | Tight | ~0.5h | OEM Verified |
Show expert analysisTechnical: **Running load:** 1500 W (high setting). **Surge:** 1500 W (resistive heating element, no inrush). **Voltage:** 120 V AC required. Ceramic heating element with fan-forced air distribution. Field note: Switch to low mode (900W) to extend runtime by 67% on battery. Thermostat cycling helps too โ once the room reaches target temp, draw drops to zero between cycles. How long can I heat a room on a portable power station? At 1500W on high, a 2000Wh station (1400Wh usable) provides roughly 1 hour of continuous heat. On low (900W), that extends to about 1.5 hours. Thermostat cycling extends these estimates further. | |||||
| De'Longhi TRD40615E (Oil-Filled Radiator) | 1,500W | 1,500W | Tight | ~0.5h | OEM Verified |
Show expert analysisTechnical: **Running load:** 1500 W (high setting). **Surge:** 1500 W (resistive heating, no inrush). **Voltage:** 120 V AC required. Oil-filled radiator with thermal mass โ continues radiating heat after power is cut, unlike ceramic or fan heaters. Field note: Oil-filled radiators are the best space heater type for battery backup. The thermal mass means the unit keeps heating the room even during thermostat off-cycles or after you turn it off โ stretching your battery further than a ceramic or fan heater. Is an oil-filled radiator better than a ceramic heater on battery? For battery efficiency, yes. The oil reservoir stores heat and radiates it passively during thermostat off-cycles. A ceramic heater stops heating the moment power cuts. Both draw 1500W on high, but the radiator delivers more total warmth per Wh consumed. | |||||
| Vornado VH200 (Whole Room Vortex) | 1,500W | 1,500W | Tight | ~0.5h | OEM Verified |
Show expert analysisTechnical: **Running load:** 1500 W (high setting). **Surge:** 1500 W (resistive heating, no inrush). **Voltage:** 120 V AC required. Vortex air circulation distributes heat throughout the room more evenly than directional heaters. Field note: The 750W low setting is useful on battery โ it halves power draw while still circulating warm air via the vortex fan. On a 2000Wh station, low mode provides nearly 2 hours of whole-room heating vs 1 hour on high. Can I use the Vornado VH200 on low mode to save battery? Yes โ low mode draws 750W, half of the 1500W high setting. This doubles your runtime on a portable power station. The vortex circulation still distributes heat effectively at the lower setting. | |||||
This unit ranks #4 of 23 compatible generators for this device by buffered margin (Balanced class).
23 of 33 generators are SAFE+TIGHT for Space Heater (1,500W).
Fit class uses buffered needs (running and surge) for this device.
Winter Storm Backup
Select Your Model:
These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.
Free Tools
This unit can handle typical compressor-based loads like refrigerators and window AC units where startup surge falls within the 3000W envelope. The 1070Wh capacity supports moderate runtime on continuous loads under 1500W. It can start most residential sump pumps and small well pumps where inrush demand does not exceed the rated surge threshold.
LFP chemistry provides a stable platform for managing high-current transients during motor startup events. The 3000W surge rating allows the unit to absorb brief inrush currents without shutdown, though users must verify compatibility with specific appliances. Source: Jackery Explorer 1000 v2 User Manual (Sept 2024) (manufacturer documentation).
Keep your Space Heater (1,500W) running with solar โข MPPT: 16โ 60V โข Max: 400W
Official 200W Panel
Smart Value 200W Panel
Adapter required: MC4 -> DC8020.
Smart Value 200W Panel
Adapter required: MC4 -> DC8020.
Yes, but it's tight. The Space Heater (1,500W) draws 1500W running / 1500W surge. With a 10% safety buffer, the safe targets are 1651W / 1651W. The Jackery Explorer 1000 v2 provides 1500W / 3000W โ it clears raw specs but leaves minimal headroom for the buffer.
Approximately 0.5 hours, based on the Space Heater (1,500W)'s 1500W draw and the Explorer 1000 v2's 1070Wh capacity (70% usable after real-world losses).
Power Tip: To get the most out of your Explorer 1000 v2, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.