Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
No - this pairing is underpowered. Safe target ~1075W running / 4169W surge; the generator provides 300W / 300W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
1,075W required -> 300W available (775W short)
Startup peak with safety buffer applied.
4,169W required -> 300W available (3,869W short)
Alternative startup path with reduced inrush.
1,876W required -> 300W available (1,576W short)
Runtime context only. It does not change the electrical compatibility verdict.
Runtime estimate appears after running and surge gates pass.
Power bars show required versus available output for each gate.
See generators that pass nativelyQuick compatibility, required headroom, and model-specific context at a glance.
0 of 3 models are SAFE or TIGHT. Most demanding model: Midea EasyDry MDP70SR71 (70 Pint) (3,335W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Midea EasyDry MDP70SR71 (70 Pint) | 690W | 3,335W | Fail | โ | OEM Manual |
Show expert analysisTechnical: **Voltage:** 120V AC required. **Running load:** 690W. **Surge:** 3335W at startup (compressor-driven). Only power stations with inverter surge capacity โฅ3335W and continuous output โฅ690W are candidates. Field note: Verify the power station's surge window duration. Short-duration surge ratings may not accommodate refrigerant compressor startup transients reliably. Can I run this dehumidifier on a portable power station overnight? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. It depends on the station's surge capacity and battery size. | |||||
| Midea EasyDry MDP70PR71 with Pump (70 Pint) | 690W | 3,335W | Fail | โ | OEM Manual |
Show expert analysisTechnical: **Running load:** 690 W. **Surge demand:** 3,335 W at compressor start. Requires 120V AC output. Power station must deliver the full surge envelope without tripping overcurrent protection. Field note: Ensure your power station's inverter can handle the 3,335 W surge without shutdown. Verify outlet capacity exceeds continuous draw. Can I run this dehumidifier on a portable power station? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. Most portable units cannot meet the surge requirement. | |||||
| Haier HEN70ETF (70 Pint) | 860W | 2,580W | Fail | โ | OEM Verified |
Show expert analysisTechnical: **Running load:** 860W. **Surge:** 2580W at startup. Requires 120V AC output. Power station must sustain 860W continuous and handle 2580W compressor inrush without tripping. Field note: Size the power station to at least 125% of running load (1075W minimum output) to avoid nuisance shutdowns during concurrent household draw. Can I run this dehumidifier overnight on a portable power station? Only if your power source can supply at least 860W continuous and 2580W surge at 120V. Most portable units lack sufficient capacity for full-day basement moisture control. | |||||
This unit is outside the compatible set; 17 of 33 generators pass SAFE/TIGHT for this device.
17 of 33 generators are SAFE+TIGHT for Dehumidifier (70 Pint).
Fit class uses buffered needs (running and surge) for this device.
Basement Moisture Control
Select Your Model:
These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.
These generators meet Dehumidifier (70 Pint)'s voltage, running, and surge requirements.
3000W โข 2042Wh
Lowest capacity that still clears surge + running load.
3600W โข 3600Wh
Expandable to 25000Wh.
Free Tools
No. The Anker SOLIX C300 falls short on both running (300W offered vs 1075W needed) and surge (300W offered vs 4169W needed). Safe targets include a 25% buffer for the Dehumidifier (70 Pint)'s compressor load profile.
No reliable runtime estimate โ this pairing is not compatible. The Anker SOLIX C300 cannot safely power the Dehumidifier (70 Pint). See compatible alternatives above for power stations that meet this device's requirements.
Power Tip: To get the most out of your SOLIX C300, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Dehumidifier (70 Pint)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Haier HEN70ETF (860W). Surge worst case = Midea EasyDry MDP70SR71 (3335W).
Anker SOLIX C300 User Manual (EN-US)