Skip to main content
GeneratorChecker

Can the SOLIX C800 Plus Run an Electric Stove? It Depends on Your Model

1 of 3 models are compatible with this generator.

Jump to model-specific results โ†“

Power Margin Analysis

1200W / 1600W Capacity
Running Up to 100W headroom on lighter models; 781W short on demanding models
1100W to 1981W required
Surge Up to 500W headroom on lighter models; 381W short on demanding models
1100W to 1981W required

Decision Gate Waterfall

Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.

1

Voltage Gate

PASS

Device output type must match generator output.

120V required -> 120V available

2

Running Gate

PARTIAL

Continuous draw with safety buffer applied.

1,100W to 1,981W required -> 1,200W available (100W headroom on lighter models)

Required 1,100W to 1,981W required
Available 1,200W
3

Surge Gate

PARTIAL

Startup peak with safety buffer applied.

1,100W to 1,981W required -> 1,600W available (500W headroom on lighter models)

Required 1,100W to 1,981W required
Available 1,600W
4

Runtime Insight

INFO

Runtime context only. It does not change the electrical compatibility verdict.

Continuous estimate: 0.3h

Device profile reference: up to 1h per day.

Power bars show required versus available output for each gate.

View full compatibility report

Decision Snapshot

Quick compatibility, required headroom, and model-specific context at a glance.

โšก
1200W
Running Power
๐Ÿ”‹
768Wh
Capacity
โฑ๏ธ
~0.3h
Est. Runtime
โ˜€๏ธ
300W
Solar Input

Quick Compatibility Check

  1. 1 1 of 3 models are compatible with the SOLIX C800 Plus.
  2. 2 Model requirements range from 1000W to 1800W running watts.
  3. 3 See the model-specific results table for per-model verdicts.

Model-Specific Results

1 of 3 models are SAFE or TIGHT. Most demanding model: Duxtop Portable Induction Cooktop (1800W) (1,800W surge).

Model Running Surge Verdict Runtime Source
Duxtop Portable Induction Cooktop (1800W) 1,800W 1,800W Fail โ€” OEM Manual
Show expert analysis

Technical: **Running load:** 1800 W. **Surge:** 1800 W (resistive heating element, no inrush spike). **Voltage:** 120 V AC required. Power station must sustain 1800 W continuous output on AC inverter.

Field note: Verify power station inverter rating is at least 2000 W continuous to allow headroom. Resistive load provides stable draw without cyclic spikes.

Can I run this induction cooktop on a 1500 W power station?

Only if your power source can supply at least 1800W continuous and 1800W surge at 120V.

Cuisinart CB-30 Cast-Iron Single Burner 1,300W 1,300W Fail โ€” OEM Manual
Show expert analysis

Technical: **Running load:** 1300 W at 120V. **Surge:** 1300 W (resistive heating element, no motor startup). Requires power station with continuous 1300 W rating and 120V AC outlet.

Field note: Verify power station continuous output meets or exceeds 1300 W. Insufficient headroom will trigger overload shutdown during cooking.

Can I use this burner with a 1000W power station?

Only if your power source can supply at least 1300W continuous and 1300W surge at 120V.

Ovente BGC101S Single Electric Burner 1,000W 1,000W Safe ~0.5h OEM Manual
Show expert analysis

Technical: **Running load:** 1000 W. **Surge:** 1000 W. **Voltage:** 120 V AC. Resistive heating element draws steady current with no inrush spike. Power station must supply clean 120 V output and sustain 1000 W continuous.

Field note: Verify power station AC outlet delivers rated continuous output. Undersized inverters will overheat or shut down under sustained resistive load.

Can I use this burner with a 500 Wh portable power station?

Only if your power source can supply at least 1000W continuous and 1000W surge at 120V. Runtime would be approximately 30 minutes before depletion, provided inverter does not thermally limit first.

How This Pairing Performs Across Our Database

This unit is outside the compatible set; 21 of 33 generators pass SAFE/TIGHT for this device.

How Electric Stove (Single Burner) Performs Across 33 Tested Generators

21 of 33 generators are SAFE+TIGHT for Electric Stove (Single Burner).

21 Safe+Tight
Safe 16 (48%)
Tight 5 (15%)
Fail 12 (36%)

Power Comparison: Anker SOLIX C800 Plus vs Top Alternatives for Electric Stove (Single Burner)

Fit class uses buffered needs (running and surge) for this device.

Specs & Surge Analysis

Electric Stove (Single Burner)
Kitchen Appliances

Electric Stove (Single Burner)

Portable Cooking

1800W
Running
1800W
Surge
120V
Required

True Surgeโ„ข Analysis

Safety Buffer: +10%
Running Power Usage 92% to 165% Utilization
1100W to 1981W required 1200W Capacity
Up to 100W headroom on lighter models; 781W short on demanding models
Surge/Startup Peak 69% to 124% Utilization
1100W to 1981W required 1600W Capacity
Up to 500W headroom on lighter models; 381W short on demanding models
Voltage Match 120V โ†” 120V โœ“

Startup Surge Visual

โš ๏ธ Before You Buy: Connection Check
Amperage check

This load may exceed a standard 15A outlet. Verify your station has a higher-amperage outlet (20A/30A) before purchase.

Generator Insights

The 1600W surge rating can support startup sequences for refrigerator compressors, well pumps, and similar inductive motor loads that draw 25 to 33 percent over running current during initial engagement. Once running, the 1200W continuous output can handle typical kitchen appliances, electronics, and power tools within rated limits. This combination addresses both inrush events and sustained runtime needs in backup scenarios.

This unit uses LFP chemistry, a battery architecture chosen for thermal stability in consumer power stations. The 768Wh capacity and 1200W continuous output allow sustained operation without thermal stress under typical residential loads. Source: Anker SOLIX C800 Plus Tech Specs (manufacturer documentation).

Extend Runtime with Solar

Keep your Electric Stove (Single Burner) running with solar โ€ข MPPT: 11โ€“ 60V โ€ข Max: 300W

Anker undefined Official

Anker

100W Panel

1 Hour Sun =
+0h per sun hour
MC4 -> XT60
Full in ~11h

Adapter required: MC4 -> XT60.

Bluetti undefined Smart Value

Bluetti

200W Panel

1 Hour Sun =
+0.1h per sun hour
MC4 -> XT60
Full in ~5.5h

Adapter required: MC4 -> XT60.

BougeRV undefined Smart Value

BougeRV

200W Panel

1 Hour Sun =
+0.1h per sun hour
MC4 -> XT60
Full in ~5.5h

Adapter required: MC4 -> XT60.

Technical Analysis

Spec-Based โ€ข No Guarantees

Technical Breakdown

Running load: 1800 W. Surge: 1800 W (resistive heating element). Voltage: 120 V AC required. Power station must supply continuous 1800 W minimum.

Expected Behavior

Estimated runtime: ~0.3h. Resistive heating draws constant 1800 W when active. Daily usage of 1 hour consumes approximately 1800 Wh.

Field Note

Most induction cooktops offer adjustable power levels (200โ€“1800W). For RV or camping use, cooking on a lower setting (600โ€“800W) stretches battery runtime significantly while still bringing water to a boil. Many van lifers switching from propane to electric rely on this approach to stay within their station's capacity.

Frequently Asked Questions

Can the Anker SOLIX C800 Plus power an Electric Stove?

It depends on the model. 1 of 3 Electric Stove (Single Burner) models are compatible with the Anker SOLIX C800 Plus. See the model-specific results table for exact verdicts per model.

How long will the SOLIX C800 Plus run an Electric Stove?

It depends on the model. Compatible models run approximately 0.5โ€“0.5 hours on the SOLIX C800 Plus. 2 of 3 models are not compatible. See the model-specific results for details.

Efficiency Hack: Large appliances like the Electric Stove (Single Burner) cycle on and off. To maximize the 0.3 hours of runtime, try to minimize how often you open the device or introduce heat loads.

Compare all 33 generators for the Electric Stove (Single Burner)

Ranked by budget, runtime, and overall compatibility.

See full ranking
Technical Sourcing & Verification
ID: anker-solix-c800-plus-electric-stove-single
๐Ÿ›๏ธ Device Data Source
Engineering Est. Safety Factor Applied

Derived from variant list (max of variants). Running worst case = Duxtop Portable Induction Cooktop 1800W (1800W). Surge = running (resistive heating element โ€” no motor inrush).

โšก Generator Specs Source
OEM Verified

Anker SOLIX C800 Plus User Manual (EN-US)

Methodology informed by US Department of Energy (DOE) & EIA references where applicable. Our methodology โ†’

Compare these models

Similar-output alternatives you can compare side by side.