Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
3 of 3 models are compatible with this generator.
Jump to model-specific results โSame decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
863W to 1,075W required -> 2,600W available (1,525W to 1,737W headroom)
Startup peak with safety buffer applied.
3,225W to 4,169W required -> 3,600W available (375W headroom on lighter models)
Alternative startup path with reduced inrush.
1,876W required -> 3,600W available (1,724W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 1.7h
Device profile reference: up to 24h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Midea EasyDry MDP70SR71 (70 Pint) (3,335W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Midea EasyDry MDP70SR71 (70 Pint) | 690W | 3,335W | Tight | ~2.1h | OEM Manual |
Show expert analysisTechnical: **Voltage:** 120V AC required. **Running load:** 690W. **Surge:** 3335W at startup (compressor-driven). Only power stations with inverter surge capacity โฅ3335W and continuous output โฅ690W are candidates. Field note: Verify the power station's surge window duration. Short-duration surge ratings may not accommodate refrigerant compressor startup transients reliably. Can I run this dehumidifier on a portable power station overnight? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. It depends on the station's surge capacity and battery size. | |||||
| Midea EasyDry MDP70PR71 with Pump (70 Pint) | 690W | 3,335W | Tight | ~2.1h | OEM Manual |
Show expert analysisTechnical: **Running load:** 690 W. **Surge demand:** 3,335 W at compressor start. Requires 120V AC output. Power station must deliver the full surge envelope without tripping overcurrent protection. Field note: Ensure your power station's inverter can handle the 3,335 W surge without shutdown. Verify outlet capacity exceeds continuous draw. Can I run this dehumidifier on a portable power station? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. Most portable units cannot meet the surge requirement. | |||||
| Haier HEN70ETF (70 Pint) | 860W | 2,580W | Safe | ~1.7h | OEM Verified |
Show expert analysisTechnical: **Running load:** 860W. **Surge:** 2580W at startup. Requires 120V AC output. Power station must sustain 860W continuous and handle 2580W compressor inrush without tripping. Field note: Size the power station to at least 125% of running load (1075W minimum output) to avoid nuisance shutdowns during concurrent household draw. Can I run this dehumidifier overnight on a portable power station? Only if your power source can supply at least 860W continuous and 2580W surge at 120V. Most portable units lack sufficient capacity for full-day basement moisture control. | |||||
This unit ranks #4 of 17 compatible generators for this device by buffered margin (Overkill class).
17 of 33 generators are SAFE+TIGHT for Dehumidifier (70 Pint).
Fit class uses buffered needs (running and surge) for this device.
Basement Moisture Control
Select Your Model:
These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.
Free Tools
With 3600W surge capacity, this unit can handle typical startup loads from refrigerator compressors, well pumps, and similar inductive motors. The 2600W running output supports sustained operation of multiple mid-draw appliances simultaneously. The 2073Wh capacity provides runtime flexibility for extended outages or off-grid scenarios.
This unit uses LFP chemistry, a stable lithium configuration widely adopted in residential backup systems. The manufacturer reports surge handling to 3600W, though independent verification of thermal performance and overcurrent protection was not provided. Source: BLUETTI Elite 200 V2 Official Spec Sheet (manufacturer documentation).
Keep your Dehumidifier (70 Pint) running with solar โข MPPT: 11โ 60V โข Max: 1000W
Official 350W Panel
Adapter required: MC4 -> XT60.
Smart Value 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 400W Panel
Adapter required: MC4 -> XT60.
It depends on the model. 3 of 3 Dehumidifier (70 Pint) models are compatible with the Bluetti Elite 200 V2. See the model-specific results table for exact verdicts per model.
It depends on the model. Compatible models run approximately 1.7โ2.1 hours on the Elite 200 V2. 0 of 3 models are not compatible. See the model-specific results for details.
With 1195W allocated to the Dehumidifier (70 Pint), the Elite 200 V2 still has ~25W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your Elite 200 V2, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Dehumidifier (70 Pint)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Haier HEN70ETF (860W). Surge worst case = Midea EasyDry MDP70SR71 (3335W).
BLUETTI Elite 200 V2 User Manual
Similar-output alternatives you can compare side by side.