Voltage Gate
PASSDevice output type must match generator output.
240V required -> 120V/240V available
1 of 3 models are compatible with this generator.
Jump to model-specific results โSame decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
240V required -> 120V/240V available
Continuous draw with safety buffer applied.
4,255W to 5,075W required -> 4,000W available (255W to 1,075W short)
Startup peak with safety buffer applied.
6,383W to 26,695W required -> 8,000W available (1,617W headroom on lighter models)
Alternative startup path with reduced inrush.
12,013W required -> 8,000W available (4,013W short)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 0.7h
Device profile reference: up to 8h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
1 of 3 models are SAFE or TIGHT. Most demanding model: Goodman GSXN4 03610A (3-Ton, 14.3 SEER2) (21,356W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Goodman GSXN4 03610A (3-Ton, 14.3 SEER2) | 3,899W | 21,356W | Fail | โ | OEM Manual |
Show expert analysisTechnical: **Running load:** 3899W from compressor RLA (16.0A) + condenser fan FLA (0.95A) at 230V. **Startup surge:** 21356W from compressor LRA (91.9A) + fan FLA at 230V. **Voltage:** 240V split-phase required. Single-stage scroll compressor with PSC condenser fan motor. Field note: The GSXN4 is Goodman's entry-level SEER2 condenser (14.3 SEER2). At 91.9A LRA, most consumer portable power stations cannot start this unit without a hard-start kit. Even with a soft-start kit, the reduced surge (~9,610W) typically exceeds consumer inverter limits. Can any portable power station start a Goodman 3-ton central AC? The 21,356W startup surge exceeds most consumer portable power stations. A soft-start kit reduces inrush but still requires approximately 9,610W surge capacity at 240V. | |||||
| Trane 4TWR4036D (3-Ton, XR14 Heat Pump) | 4,060W | 18,389W | Fail | โ | OEM Manual |
Show expert analysisTechnical: **Running load:** 4060W from compressor RLA (16.7A) + condenser fan FLA (0.95A) at 230V. **Startup surge:** 18389W from compressor LRA (79A) + fan FLA at 230V. **Voltage:** 240V split-phase required. Climatuff scroll compressor with PSC condenser fan motor. Field note: The Trane XR14 heat pump operates identically to an AC condenser in cooling mode. Its 79A LRA is lower than Goodman's 91.9A but still typically beyond consumer portable power station surge limits. This unit is unlikely to run on portable power without a soft-start kit and a large 240V inverter. Is the Trane XR14 easier on a generator than the Goodman GSXN4? Lower startup surge (18,389W vs 21,356W) but higher running watts (4,060W vs 3,899W). Both remain far beyond portable power station limits without a soft-start kit. | |||||
| Lennox SL28XCV-036 (3-Ton, 28 SEER Variable-Speed) | 3,404W | 5,106W | Tight | ~0.8h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 3404W from compressor input (12A) + condenser fan FLA (2.8A) at 230V. **Estimated startup surge:** 5106W at 1.5x running โ no traditional LRA because the SL28XCV uses a variable-speed inverter compressor that ramps gradually. **Voltage:** 240V split-phase required. Field note: The SL28XCV's inverter compressor eliminates the massive LRA spike that makes conventional central AC impossible for portable power. At ~5,106W estimated surge, this is the only 3-ton variant in this set that could theoretically be started by a large consumer power station with 240V output. However, 3,404W continuous draw still demands substantial battery capacity. Why does this Lennox have so much lower startup surge than other 3-ton units? The SL28XCV uses a variable-speed inverter compressor that ramps up gradually instead of hard-starting. This eliminates the 79-92A locked-rotor inrush of conventional scroll compressors, reducing estimated surge from ~20,000W to ~5,100W. | |||||
This unit is outside the compatible set; 1 of 33 generators pass SAFE/TIGHT for this device.
1 of 33 generators are SAFE+TIGHT for Central AC (3-Ton).
Fit class uses buffered needs (running and surge) for this device.
Whole-Home Cooling
Select Your Model:
This device typically needs 240V split-phase or a hardwired connection. Most portable stations are 120V-only. Verify the plug type and voltage on the device label/manual before purchase.
These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.
Free Tools
The 8000W surge rating can support typical compressor startup in residential air conditioners, well pumps, and refrigeration equipment. Most single-phase motor loads under 2HP can start on this surge budget. The 4000W continuous capacity can handle simultaneous operation of multiple circuits including HVAC blowers, lighting, and standard appliances during extended outages.
This unit provides 4096Wh of LFP battery capacity with 4000W continuous and 8000W surge output capability. Source: EcoFlow DELTA Pro 3 User Manual v1.1 (AC Output Specifications) (manufacturer documentation). The LFP chemistry offers thermal stability compared to older lithium-ion chemistries, though all battery systems require proper ventilation and adherence to installation guidelines.
Keep your Central AC (3-Ton) running with solar โข MPPT: 30โ 150V โข Max: 2600W
Official 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 350W Panel
Adapter required: MC4 -> XT60.
It depends on the model. 1 of 3 Central AC (3-Ton) models are compatible with the EcoFlow DELTA Pro 3. See the model-specific results table for exact verdicts per model.
It depends on the model. Compatible models run approximately 0.8โ0.8 hours on the DELTA Pro 3. 2 of 3 models are not compatible. See the model-specific results for details.
Power Tip: To get the most out of your DELTA Pro 3, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Central AC (3-Ton)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Trane 4TWR4036D (4060W). Surge worst case = Goodman GSXN4 03610A (21356W).
EcoFlow DELTA Pro 3 User Manual v1.1 (AC Output Specifications)