Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V/240V available
Yes - DELTA Pro 3 has enough running and surge power for the Dehumidifier (70 Pint). Target ~1075W running / 4169W surge; the generator provides 4000W / 8000W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V/240V available
Continuous draw with safety buffer applied.
1,075W required -> 4,000W available (2,925W headroom)
Startup peak with safety buffer applied.
4,169W required -> 8,000W available (3,831W headroom)
Alternative startup path with reduced inrush.
1,876W required -> 8,000W available (6,124W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 3.3h
Device profile reference: up to 24h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Midea EasyDry MDP70SR71 (70 Pint) (3,335W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Midea EasyDry MDP70SR71 (70 Pint) | 690W | 3,335W | Safe | ~4.2h | OEM Manual |
Show expert analysisTechnical: **Voltage:** 120V AC required. **Running load:** 690W. **Surge:** 3335W at startup (compressor-driven). Only power stations with inverter surge capacity โฅ3335W and continuous output โฅ690W are candidates. Field note: Verify the power station's surge window duration. Short-duration surge ratings may not accommodate refrigerant compressor startup transients reliably. Can I run this dehumidifier on a portable power station overnight? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. It depends on the station's surge capacity and battery size. | |||||
| Midea EasyDry MDP70PR71 with Pump (70 Pint) | 690W | 3,335W | Safe | ~4.2h | OEM Manual |
Show expert analysisTechnical: **Running load:** 690 W. **Surge demand:** 3,335 W at compressor start. Requires 120V AC output. Power station must deliver the full surge envelope without tripping overcurrent protection. Field note: Ensure your power station's inverter can handle the 3,335 W surge without shutdown. Verify outlet capacity exceeds continuous draw. Can I run this dehumidifier on a portable power station? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. Most portable units cannot meet the surge requirement. | |||||
| Haier HEN70ETF (70 Pint) | 860W | 2,580W | Safe | ~3.3h | OEM Verified |
Show expert analysisTechnical: **Running load:** 860W. **Surge:** 2580W at startup. Requires 120V AC output. Power station must sustain 860W continuous and handle 2580W compressor inrush without tripping. Field note: Size the power station to at least 125% of running load (1075W minimum output) to avoid nuisance shutdowns during concurrent household draw. Can I run this dehumidifier overnight on a portable power station? Only if your power source can supply at least 860W continuous and 2580W surge at 120V. Most portable units lack sufficient capacity for full-day basement moisture control. | |||||
This unit ranks #14 of 17 compatible generators for this device by buffered margin (Overkill class).
17 of 33 generators are SAFE+TIGHT for Dehumidifier (70 Pint).
Fit class uses buffered needs (running and surge) for this device.
Basement Moisture Control
Select Your Model:
These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.
Free Tools
The 8000W surge rating can support typical compressor startup in residential air conditioners, well pumps, and refrigeration equipment. Most single-phase motor loads under 2HP can start on this surge budget. The 4000W continuous capacity can handle simultaneous operation of multiple circuits including HVAC blowers, lighting, and standard appliances during extended outages.
This unit provides 4096Wh of LFP battery capacity with 4000W continuous and 8000W surge output capability. Source: EcoFlow DELTA Pro 3 User Manual v1.1 (AC Output Specifications) (manufacturer documentation). The LFP chemistry offers thermal stability compared to older lithium-ion chemistries, though all battery systems require proper ventilation and adherence to installation guidelines.
Keep your Dehumidifier (70 Pint) running with solar โข MPPT: 30โ 150V โข Max: 2600W
Official 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 350W Panel
Adapter required: MC4 -> XT60.
Yes. The EcoFlow DELTA Pro 3 provides 4000W running / 8000W surge. The Dehumidifier (70 Pint) needs 1075W / 4169W (including 25% buffer). That leaves 2925W of running headroom and 3831W of surge margin.
Approximately 3.3 hours, based on the Dehumidifier (70 Pint)'s 860W draw and the DELTA Pro 3's 4096Wh capacity (70% usable after real-world losses).
With 1740W allocated to the Dehumidifier (70 Pint), the DELTA Pro 3 still has ~600W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your DELTA Pro 3, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Dehumidifier (70 Pint)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Haier HEN70ETF (860W). Surge worst case = Midea EasyDry MDP70SR71 (3335W).
EcoFlow DELTA Pro 3 User Manual v1.1 (AC Output Specifications)
Similar-output alternatives you can compare side by side.