Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V/240V available
Yes - DELTA Pro 3 has enough running and surge power for the Medical Nebulizer Machine. Target ~127W running / 127W surge; the generator provides 4000W / 8000W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V/240V available
Continuous draw with safety buffer applied.
127W required -> 4,000W available (3,873W headroom)
Startup peak with safety buffer applied.
127W required -> 8,000W available (7,873W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 26.1h
Device profile reference: up to 2h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Drive Medical Power Neb Ultra (110W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Omron CompAir NE-C801 | 12W | 12W | Safe | ~238.9h | Engineering Est. |
Show expert analysisTechnical: **Running load:** ~12W AC (12V ร 0.8A DC via external AC adapter). **Surge:** ~12W (DC-powered, no motor inrush at the AC side). **Voltage:** 100-240V AC input (universal adapter). This is the lowest-draw nebulizer in this comparison by a wide margin โ the external DC adapter eliminates AC-side compressor surge. Field note: The Omron NE-C801 is the most portable-power-friendly nebulizer available. At only 12W, even a 150Wh power bank with AC output can provide over 10 hours of therapy. The DC adapter also means modified sine wave inverters are less of a concern โ the adapter handles AC conversion internally. Always carry a backup adapter. Can I run the Omron CompAir nebulizer on a small portable power station? Only if your power source can supply at least 12W continuous at 120V. This device draws minimal power and is compatible with virtually any power station or battery pack with an AC outlet. | |||||
| PARI PRONEB Max | 98W | 98W | Safe | ~29.3h | Gov. Database |
Show expert analysisTechnical: **Running load:** 98W (FDA 510(k) filing, under normal load). **Surge:** 98W (OEM surge data not published โ shaded pole motors have low inrush characteristics). **Voltage:** 120V AC, 60 Hz. The PRONEB Max uses an AC-powered shaded pole motor driving an oil-free piston compressor at 30+ psig. Field note: The PARI PRONEB Max is the current hospital-grade standard, replacing the PARI Vios. At 98W it requires a power station with at least 200W continuous output. For respiratory therapy on battery backup, pure sine wave output is recommended โ AC shaded pole motors may run hot or lose efficiency on modified sine wave inverters. This is a life-sustaining medical device: always have a backup power source. Can I use the PARI PRONEB Max nebulizer during a power outage with a portable power station? Only if your power source can supply at least 98W continuous at 120V. Pure sine wave output is recommended for this AC motor-driven compressor. Always maintain a backup power source for life-sustaining respiratory therapy. | |||||
| Drive Medical Power Neb Ultra | 110W | 110W | Safe | ~26.1h | OEM Manual |
Show expert analysisTechnical: **Running load:** 110W (110 VA OEM rated โ apparent power, conservative for sizing). **Surge:** 110W (OEM surge data not published โ piston compressor motor has some startup inrush but OEM does not specify). **Voltage:** 120V AC, 60 Hz. The Power Neb Ultra uses a piston-driven AC motor compressor producing 30+ psig at 8 LPM free air flow. Field note: The Drive Medical Power Neb Ultra is the most common insurance-reimbursed nebulizer in the US. At 110 VA it draws the most power in this comparison. Pure sine wave output is recommended for the AC piston motor. The 110 VA rating is apparent power โ real watts may be lower, but size your power station to the VA rating for safety. This is a medical device: always have a backup power source. Can I run the Drive Medical nebulizer on a portable power station during an outage? Only if your power source can supply at least 110W continuous at 120V. Pure sine wave output is recommended for this AC motor-driven compressor. Always maintain a backup power source for respiratory therapy. | |||||
This unit ranks #30 of 33 compatible generators for this device by buffered margin (Overkill class).
33 of 33 generators are SAFE+TIGHT for Medical Nebulizer Machine.
Fit class uses buffered needs (running and surge) for this device.
Respiratory Therapy Session
Select Your Model:
Free Tools
The 8000W surge rating can support typical compressor startup in residential air conditioners, well pumps, and refrigeration equipment. Most single-phase motor loads under 2HP can start on this surge budget. The 4000W continuous capacity can handle simultaneous operation of multiple circuits including HVAC blowers, lighting, and standard appliances during extended outages.
This unit provides 4096Wh of LFP battery capacity with 4000W continuous and 8000W surge output capability. Source: EcoFlow DELTA Pro 3 User Manual v1.1 (AC Output Specifications) (manufacturer documentation). The LFP chemistry offers thermal stability compared to older lithium-ion chemistries, though all battery systems require proper ventilation and adherence to installation guidelines.
Keep your Medical Nebulizer Machine running with solar โข MPPT: 30โ 150V โข Max: 2600W
Official 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 350W Panel
Adapter required: MC4 -> XT60.
Yes. The EcoFlow DELTA Pro 3 provides 4000W running / 8000W surge. The Medical Nebulizer Machine needs 127W / 127W (including 15% buffer). That leaves 3873W of running headroom and 7873W of surge margin.
Approximately 26.1 hours, based on the Medical Nebulizer Machine's 110W draw and the DELTA Pro 3's 4096Wh capacity (70% usable after real-world losses).
With 335W allocated to the Medical Nebulizer Machine, the DELTA Pro 3 still has ~2755W of margin. These devices could run simultaneously:
Pro Tip for Medical Users: According to energy reports, turning off the humidifier on your Medical Nebulizer Machine can double your runtime. Using a DC cable instead of the AC plug is also recommended to avoid inverter inefficiency.
Compare all 33 generators for the Medical Nebulizer Machine
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Worst case = Drive Medical Power Neb Ultra (110 VA OEM). Surge data not published by any manufacturer in this class โ set equal to running as conservative baseline.
EcoFlow DELTA Pro 3 User Manual v1.1 (AC Output Specifications)
Similar-output alternatives you can compare side by side.