Skip to main content
GeneratorChecker

Yes, the Delta Pro Ultra X can run a Pancake Air Compressor

Yes - Delta Pro Ultra X has enough running and surge power for the Pancake Air Compressor (6-Gallon). Target ~2025W running / 10429W surge; the generator provides 12000W / 24000W.

Power Margin Analysis

12000W / 24000W Capacity
Running 9975W headroom
2025W required
Surge 13571W headroom
10429W required

Decision Gate Waterfall

Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.

1

Voltage Gate

PASS

Device output type must match generator output.

120V required -> 120V/240V available

2

Running Gate

PASS

Continuous draw with safety buffer applied.

2,025W required -> 12,000W available (9,975W headroom)

Required 2,025W required
Available 12,000W
3

Surge Gate

PASS

Startup peak with safety buffer applied.

10,429W required -> 24,000W available (13,571W headroom)

Required 10,429W required
Available 24,000W
3b

With Soft-Start

PASS

Alternative startup path with reduced inrush.

4,693W required -> 24,000W available (19,307W headroom)

Required 4,693W
Available 24,000W
4

Runtime Insight

INFO

Runtime context only. It does not change the electrical compatibility verdict.

Continuous estimate: 2.7h

Device profile reference: up to 1h per day.

Power bars show required versus available output for each gate.

View full compatibility report

Decision Snapshot

Quick compatibility, required headroom, and model-specific context at a glance.

โšก
12000W
Running Power
๐Ÿ”‹
6144Wh
Capacity
โฑ๏ธ
~2.7h
Est. Runtime
โ˜€๏ธ
10000W
Solar Input

Quick Compatibility Check

  1. 1 Running headroom: target 2025W; generator provides 12000W.
  2. 2 Surge headroom: target 10429W; generator provides 24000W.
  3. 3 Tip: leave headroom for startup spikes and warm conditions.

Model-Specific Results

3 of 3 models are SAFE or TIGHT. Most demanding model: Metabo HPT EC914S 'The Tank' (6-Gal, 1.3 HP, 200 PSI) (8,343W surge).

Model Running Surge Verdict Runtime Source
DeWalt DWFP55126 (6-Gal, 0.9 HP, 165 PSI) 1,200W 6,180W Safe ~3.6h Engineering Est.
Show expert analysis

Technical: **Running load:** 1200W from OEM rated amps (10A ร— 120V). **Estimated startup surge:** 6180W at 5.15x running (proxy from CRAFTSMAN OEM data for comparable 6-gallon pancake compressor โ€” no DeWalt starting watts published). **Voltage:** 120V AC. Oil-free pump, 0.9 HP universal motor, 165 PSI max.

Field note: The DWFP55126 is the best-selling pancake compressor in the US. Despite the modest 1200W running draw, the ~6180W startup surge means most power stations under 3000W surge capacity will trip on compressor restart. Size for surge first, not running watts.

Can a portable power station run the DeWalt DWFP55126?

Only if your power source can supply at least 1200W continuous and approximately 6180W surge at 120V. The compressor startup surge is the main limiting factor, not the running watts.

CRAFTSMAN CMEC6150 (6-Gal, 0.8 HP, 150 PSI) 1,320W 6,800W Safe ~3.3h OEM Verified
Show expert analysis

Technical: **Running load:** 1320W (OEM published). **Startup surge:** 6800W (OEM published, 5.15x running). **Voltage:** 120V AC. Oil-free pump, 0.8 HP motor, 150 PSI max. This is the only variant in this set with OEM-published starting watts.

Field note: The CRAFTSMAN OEM data reveals a critical insight: pancake compressors surge at over 5x running watts โ€” far more than the 3x NEC assumption used for many motor loads. This is because the compressor must overcome residual tank pressure on restart. Always size for the 6800W surge, not the 1320W running draw.

Why does this compressor need so much more starting power than running power?

The motor must overcome compressed air resistance in the tank at startup. CRAFTSMAN rates this model at 6800W starting versus 1320W running โ€” a 5.15x ratio. Most power stations under 3500W surge will fail to start this compressor.

Metabo HPT EC914S 'The Tank' (6-Gal, 1.3 HP, 200 PSI) 1,620W 8,343W Safe ~2.7h Engineering Est.
Show expert analysis

Technical: **Running load:** 1620W from OEM rated amps (13.5A ร— 120V). **Estimated startup surge:** 8343W at 5.15x running (proxy from CRAFTSMAN OEM data for comparable 6-gallon pancake compressor โ€” no Metabo HPT starting watts published). **Voltage:** 120V AC. Industrial motor, 1.3 HP, 200 PSI max โ€” the most powerful unit in this set.

Field note: The EC914S draws 35% more running watts and has an estimated 8343W surge โ€” this is the hardest-to-run pancake compressor in the set. Most consumer power stations cannot start it. Its 200 PSI max and 4.0 SCFM output make it a jobsite-grade tool that demands jobsite-grade power.

Why does the Metabo HPT need so much more power than the DeWalt?

At 1.3 HP versus 0.9 HP, the EC914S delivers 54% more air flow and 21% higher max pressure. That extra performance requires 1620W running and an estimated 8343W startup surge โ€” significantly more than entry-level 0.8-0.9 HP compressors.

How This Pairing Performs Across Our Database

This unit ranks #3 of 3 compatible generators for this device by buffered margin (Overkill class).

How Pancake Air Compressor (6-Gallon) Performs Across 33 Tested Generators

3 of 33 generators are SAFE+TIGHT for Pancake Air Compressor (6-Gallon).

3 Safe+Tight
Safe 2 (6%)
Tight 1 (3%)
Soft Start 8 (24%)
Fail 22 (67%)

Power Comparison: EcoFlow Delta Pro Ultra X vs Top Alternatives for Pancake Air Compressor (6-Gallon)

Fit class uses buffered needs (running and surge) for this device.

Specs & Surge Analysis

True Surgeโ„ข Analysis

Safety Buffer: +25%
Running Power Usage 17% Utilization
2025W required 12000W Capacity
9975W headroom
Surge/Startup Peak 43% Utilization
10429W required 24000W Capacity
13571W headroom
Voltage Match 120V โ†” 120V/240V โœ“

Generator Insights

With 24,000W surge capacity, this system can handle typical compressor startup events found in central air conditioners, well pumps, and refrigeration equipment. The 12,000W continuous rating supports sustained high-load operation across multiple circuits. At 6,144Wh usable capacity, runtime depends on connected load, but this configuration can support whole-home essentials during extended outages.

This unit uses LFP chemistry, a formulation widely recognized for thermal stability in residential backup applications. The manufacturer provides operational guidelines in their documentation, and users should follow all installation and grounding instructions. Source: EcoFlow DELTA Pro Ultra X User Manual (manufacturer documentation).

Extend Runtime with Solar

Keep your Pancake Air Compressor (6-Gallon) running with solar โ€ข MPPT: 80โ€“ 500V โ€ข Max: 10000W

EcoFlow undefined Official

EcoFlow

400W Panel

1 Hour Sun =
+0.2h per sun hour
Amp Limited
Full in ~11h

Requires 2 panels in series to reach the 80V start threshold.

Anker undefined Smart Value

Anker

400W Panel

1 Hour Sun =
+0.2h per sun hour
Amp Limited
Full in ~11h

Requires 2 panels in series to reach the 80V start threshold.

Bluetti undefined Smart Value

Bluetti

350W Panel

1 Hour Sun =
+0.2h per sun hour
Amp Limited
Full in ~8.4h

Requires 3 panels in series to reach the 80V start threshold.

Technical Analysis

Spec-Based โ€ข No Guarantees

Technical Breakdown

Running range: 1200W to 1620W depending on motor size (0.8-1.3 HP). Surge range: 6180W to 8343W โ€” pancake compressors surge at approximately 5x running watts due to compressed air resistance on restart. Voltage: 120V AC for all models.

Expected Behavior

Estimated runtime: ~2.7h. Compressors cycle between cut-in and cut-out pressure, creating repeated surge events during use. Daily energy consumption at 1 hour use ranges from 600 to 1215 Wh depending on model and duty cycle. Recommended duty cycle is 50-75% (30-45 minutes per hour max).

Field Note

Compressor startup surge is the primary compatibility bottleneck โ€” not running watts. A power station rated at 2000W continuous but only 3000W surge will fail to start any compressor in this set. OEM data shows pancake compressors surge at over 5x running, far exceeding the 3x often assumed for motor loads.

Frequently Asked Questions

Can the EcoFlow Delta Pro Ultra X power a Pancake Air Compressor?

Yes. The EcoFlow Delta Pro Ultra X provides 12000W running / 24000W surge. The Pancake Air Compressor (6-Gallon) needs 2025W / 10429W (including 25% buffer). That leaves 9975W of running headroom and 13571W of surge margin.

How long will the Delta Pro Ultra X run a Pancake Air Compressor?

Approximately 2.7 hours, based on the Pancake Air Compressor (6-Gallon)'s 1620W draw and the Delta Pro Ultra X's 6144Wh capacity (70% usable after real-world losses).

What Else Can You Run?

With 1965W allocated to the Pancake Air Compressor (6-Gallon), the Delta Pro Ultra X still has ~6015W of margin. These devices could run simultaneously:

๐Ÿ”ฅ
Space Heater (Eco)
750W
๐Ÿ’ก
LED Lamp
10W
๐Ÿ“บ
55' LED TV
80W
๐ŸŒ€
Box Fan (Medium)
60W
๐Ÿ’ป
MacBook Air/Pro
65W
๐Ÿฅช
Microwave (Running)
1000W

Power Tip: To get the most out of your Delta Pro Ultra X, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.

Compare all 33 generators for the Pancake Air Compressor (6-Gallon)

Ranked by budget, runtime, and overall compatibility.

See full ranking
Technical Sourcing & Verification
ID: ecoflow-delta-pro-ultra-x-air-compressor-pancake
๐Ÿ›๏ธ Device Data Source
Engineering Est. Safety Factor Applied

Derived from variant list (max of variants). Running worst case = Metabo HPT EC914S (1620W). Surge worst case = Metabo HPT EC914S (8343W). Surge ratio 5.15x derived from CRAFTSMAN CMEC6150 OEM-published start/run watts (6800W/1320W).

โšก Generator Specs Source
OEM Verified

EcoFlow DELTA Pro Ultra X User Manual

Methodology informed by US Department of Energy (DOE) & EIA references where applicable. Our methodology โ†’

Compare these models

Similar-output alternatives you can compare side by side.