Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V/240V available
Yes - Delta Pro Ultra X has enough running and surge power for the Dehumidifier (70 Pint). Target ~1075W running / 4169W surge; the generator provides 12000W / 24000W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V/240V available
Continuous draw with safety buffer applied.
1,075W required -> 12,000W available (10,925W headroom)
Startup peak with safety buffer applied.
4,169W required -> 24,000W available (19,831W headroom)
Alternative startup path with reduced inrush.
1,876W required -> 24,000W available (22,124W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 5.0h
Device profile reference: up to 24h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Midea EasyDry MDP70SR71 (70 Pint) (3,335W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Midea EasyDry MDP70SR71 (70 Pint) | 690W | 3,335W | Safe | ~6.2h | OEM Manual |
Show expert analysisTechnical: **Voltage:** 120V AC required. **Running load:** 690W. **Surge:** 3335W at startup (compressor-driven). Only power stations with inverter surge capacity โฅ3335W and continuous output โฅ690W are candidates. Field note: Verify the power station's surge window duration. Short-duration surge ratings may not accommodate refrigerant compressor startup transients reliably. Can I run this dehumidifier on a portable power station overnight? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. It depends on the station's surge capacity and battery size. | |||||
| Midea EasyDry MDP70PR71 with Pump (70 Pint) | 690W | 3,335W | Safe | ~6.2h | OEM Manual |
Show expert analysisTechnical: **Running load:** 690 W. **Surge demand:** 3,335 W at compressor start. Requires 120V AC output. Power station must deliver the full surge envelope without tripping overcurrent protection. Field note: Ensure your power station's inverter can handle the 3,335 W surge without shutdown. Verify outlet capacity exceeds continuous draw. Can I run this dehumidifier on a portable power station? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. Most portable units cannot meet the surge requirement. | |||||
| Haier HEN70ETF (70 Pint) | 860W | 2,580W | Safe | ~5.0h | OEM Verified |
Show expert analysisTechnical: **Running load:** 860W. **Surge:** 2580W at startup. Requires 120V AC output. Power station must sustain 860W continuous and handle 2580W compressor inrush without tripping. Field note: Size the power station to at least 125% of running load (1075W minimum output) to avoid nuisance shutdowns during concurrent household draw. Can I run this dehumidifier overnight on a portable power station? Only if your power source can supply at least 860W continuous and 2580W surge at 120V. Most portable units lack sufficient capacity for full-day basement moisture control. | |||||
This unit ranks #17 of 17 compatible generators for this device by buffered margin (Overkill class).
17 of 33 generators are SAFE+TIGHT for Dehumidifier (70 Pint).
Fit class uses buffered needs (running and surge) for this device.
Basement Moisture Control
Select Your Model:
These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.
Free Tools
With 24,000W surge capacity, this system can handle typical compressor startup events found in central air conditioners, well pumps, and refrigeration equipment. The 12,000W continuous rating supports sustained high-load operation across multiple circuits. At 6,144Wh usable capacity, runtime depends on connected load, but this configuration can support whole-home essentials during extended outages.
This unit uses LFP chemistry, a formulation widely recognized for thermal stability in residential backup applications. The manufacturer provides operational guidelines in their documentation, and users should follow all installation and grounding instructions. Source: EcoFlow DELTA Pro Ultra X User Manual (manufacturer documentation).
Keep your Dehumidifier (70 Pint) running with solar โข MPPT: 80โ 500V โข Max: 10000W
Official 400W Panel
Requires 2 panels in series to reach the 80V start threshold.
Smart Value 400W Panel
Requires 2 panels in series to reach the 80V start threshold.
Smart Value 350W Panel
Requires 3 panels in series to reach the 80V start threshold.
Yes. The EcoFlow Delta Pro Ultra X provides 12000W running / 24000W surge. The Dehumidifier (70 Pint) needs 1075W / 4169W (including 25% buffer). That leaves 10925W of running headroom and 19831W of surge margin.
Approximately 5.0 hours, based on the Dehumidifier (70 Pint)'s 860W draw and the Delta Pro Ultra X's 6144Wh capacity (70% usable after real-world losses).
With 2700W allocated to the Dehumidifier (70 Pint), the Delta Pro Ultra X still has ~6040W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your Delta Pro Ultra X, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Dehumidifier (70 Pint)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Haier HEN70ETF (860W). Surge worst case = Midea EasyDry MDP70SR71 (3335W).
EcoFlow DELTA Pro Ultra X User Manual
Similar-output alternatives you can compare side by side.