Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V/240V available
Yes - Delta Pro Ultra X has enough running and surge power for the Portable Electric Cooler. Target ~75W running / 150W surge; the generator provides 12000W / 24000W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V/240V available
Continuous draw with safety buffer applied.
75W required -> 12,000W available (11,925W headroom)
Startup peak with safety buffer applied.
150W required -> 24,000W available (23,850W headroom)
Alternative startup path with reduced inrush.
68W required -> 24,000W available (23,932W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 71.7h
Typical cycling estimate (40% duty): 179.3h
Device profile reference: up to 12h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Alpicool C20 (20L Portable Fridge) (120W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Dometic CFX3 35 (36L Compressor Cooler) | 50W | 100W | Safe | ~86.0h | OEM Verified |
Show expert analysisTechnical: **Running load:** 50 W (AC rated input, compressor active). **Surge:** 100 W (estimated 2x compressor startup). **Voltage:** 120 V AC required (also runs on 12/24V DC). Dometic's VMSO3 compressor is optimized for low power draw โ Dometic describes it as 'using less power than a 60W light bulb.' Field note: The Dometic CFX3 is the gold standard for overlanding. At 50W peak / 20W average, even a compact 500Wh power station runs it for over 24 hours. Use the 12V DC input to bypass the AC adapter and improve efficiency when connected to a power station with DC output. How long can I run a Dometic CFX3 on a portable power station? At ~20W average (compressor cycling), a 1000Wh station (700Wh usable) runs the CFX3 for about 35 hours โ easily covering a long weekend camping trip. | |||||
| BougeRV CRPRO30 (30 Qt Portable Fridge) | 45W | 90W | Safe | ~95.6h | OEM Verified |
Show expert analysisTechnical: **Running load:** 45 W (MAX mode). **Surge:** 90 W (estimated 2x compressor startup). **Voltage:** 120 V AC (or 12/24V DC). ECO mode reduces running draw to 36W. Budget-friendly alternative to Dometic with comparable performance. Field note: Use ECO mode on battery to maximize runtime โ it reduces peak draw from 45W to 36W and cycles less frequently. The BougeRV is roughly half the price of a Dometic CFX3 with similar power draw. What's the difference between MAX and ECO mode for battery life? ECO mode draws 36W vs 45W for MAX, and cycles the compressor less aggressively. On a 500Wh power station, ECO provides roughly 20+ hours vs 16 hours in MAX mode. | |||||
| Alpicool C20 (20L Portable Fridge) | 60W | 120W | Safe | ~71.7h | OEM Verified |
Show expert analysisTechnical: **Running load:** 60 W (rated maximum). **Surge:** 120 W (estimated 2x compressor startup). **Voltage:** 120 V AC (or 12/24V DC). Despite being the smallest cooler in this comparison (20L), the Alpicool C20 draws the most power due to a less efficient compressor design. Field note: The Alpicool C20 is the entry-level option at the lowest price point. It draws more power per liter of cooling capacity than the Dometic or BougeRV. For longer off-grid trips, the efficiency difference adds up โ consider a BougeRV or Dometic for multi-day camping. Is the Alpicool C20 efficient enough for solar-powered camping? At ~25W average draw, a 100W solar panel with a power station handles the C20 comfortably during daylight hours. The challenge is overnight draw when solar isn't producing โ plan for ~150-200Wh of battery reserve for 8 hours of nighttime cooling. | |||||
This unit ranks #33 of 33 compatible generators for this device by buffered margin (Overkill class).
33 of 33 generators are SAFE+TIGHT for Portable Electric Cooler.
Fit class uses buffered needs (running and surge) for this device.
Camping / Road Trip
Select Your Model:
Free Tools
With 24,000W surge capacity, this system can handle typical compressor startup events found in central air conditioners, well pumps, and refrigeration equipment. The 12,000W continuous rating supports sustained high-load operation across multiple circuits. At 6,144Wh usable capacity, runtime depends on connected load, but this configuration can support whole-home essentials during extended outages.
This unit uses LFP chemistry, a formulation widely recognized for thermal stability in residential backup applications. The manufacturer provides operational guidelines in their documentation, and users should follow all installation and grounding instructions. Source: EcoFlow DELTA Pro Ultra X User Manual (manufacturer documentation).
Keep your Portable Electric Cooler running with solar โข MPPT: 80โ 500V โข Max: 10000W
Official 400W Panel
Requires 2 panels in series to reach the 80V start threshold.
Smart Value 400W Panel
Requires 2 panels in series to reach the 80V start threshold.
Smart Value 350W Panel
Requires 3 panels in series to reach the 80V start threshold.
Yes. The EcoFlow Delta Pro Ultra X provides 12000W running / 24000W surge. The Portable Electric Cooler needs 75W / 150W (including 25% buffer). That leaves 11925W of running headroom and 23850W of surge margin.
Approximately 71.7 hours, based on the Portable Electric Cooler's 60W draw and the Delta Pro Ultra X's 6144Wh capacity (70% usable after real-world losses).
With 2415W allocated to the Portable Electric Cooler, the Delta Pro Ultra X still has ~7125W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your Delta Pro Ultra X, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Portable Electric Cooler
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Alpicool C20 (60W rated). Surge worst case = Alpicool C20 (120W, 2x compressor startup estimate). These are DC compressor coolers with AC adapters โ the adapter handles most of the compressor inrush internally, but 2x is used as conservative estimate.
EcoFlow DELTA Pro Ultra X User Manual
Similar-output alternatives you can compare side by side.