Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
This pairing clears the safety headroom. Required ~200W running and 400W surge; the RIVER 2 Max is rated 500W / 1000W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
200W required -> 500W available (300W headroom)
Startup peak with safety buffer applied.
400W required -> 1,000W available (600W headroom)
Alternative startup path with reduced inrush.
180W required -> 1,000W available (820W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 2.2h
Device profile reference: up to 24h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Frigidaire FFFU16F2VW (16 Cu. Ft. Upright, Auto-Defrost) (320W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| GE FUF17DLRWW (17.3 Cu. Ft. Upright, Frost-Free, Garage Ready) | 153W | 306W | Safe | ~2.3h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 153W estimated from 441 kWh/yr at 0.33 duty cycle. **Estimated startup surge:** 306W at 2.0x running (conservative โ no OEM LRA published). **Voltage:** 120V AC. Frost-free upright with electronic temperature control and garage-ready certification (0ยฐF to 110ยฐF ambient). Field note: Garage-ready certification means this freezer has an internal heater that activates in cold ambient conditions to keep the compressor warm. In winter garage use on battery power, energy consumption may increase โ counter-intuitive but important for sizing. The 20A on the spec sheet is the circuit breaker requirement, not the actual draw. Can a portable power station keep this GE upright freezer running during an outage? At 153W running with 306W estimated surge, most power stations above 500W continuous can handle this freezer. A 1,000 Wh battery provides roughly 14 hours of runtime at average draw. | |||||
| Frigidaire FFFU16F2VW (16 Cu. Ft. Upright, Auto-Defrost) | 160W | 320W | Safe | ~2.2h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 160W estimated from 461 kWh/yr at 0.33 duty cycle. **Estimated startup surge:** 320W at 2.0x running (conservative โ no OEM LRA published). **Voltage:** 120V AC. Auto-defrost upright with wire shelving and R-600A refrigerant. Field note: The Frigidaire is the most affordable option but also the least efficient at 461 kWh/yr. For extended outage use on battery power, the extra ~55 Wh/day versus the GE upright adds up over multi-day events. Not garage-rated โ performance may degrade in unheated spaces below 55ยฐF. How long can a portable power station run this Frigidaire freezer? At 160W running with 320W estimated surge, a 1,000 Wh power station provides roughly 13 hours at average draw. For a full 24-hour outage, budget at least 1,300 Wh of usable station capacity. | |||||
| GE FCM16DLWW (15.7 Cu. Ft. Chest, Manual Defrost, Garage Ready) | 127W | 254W | Safe | ~2.8h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 127W estimated from 277 kWh/yr at 0.25 duty cycle. **Estimated startup surge:** 254W at 2.0x running (conservative โ no OEM LRA published). **Voltage:** 120V AC. Manual-defrost chest freezer with top-opening lid and garage-ready certification (0ยฐF to 110ยฐF ambient). Field note: This is the most power-station-friendly freezer in the set. Manual defrost means no surprise heater cycles draining the battery. The chest design retains cold for 36-48 hours without power if kept closed โ buying critical time during extended outages. Garage-ready certification adds a compressor heater for cold ambient, but in summer outage scenarios it stays dormant. Why is the chest freezer so much more efficient on battery power? Three reasons: top-opening lid prevents cold air from falling out when opened, thicker insulation reduces heat gain, and manual defrost eliminates the periodic 400-600W heater cycle that upright auto-defrost models run every 12-24 hours. | |||||
This unit ranks #4 of 32 compatible generators for this device by buffered margin (Overkill class).
32 of 33 generators are SAFE+TIGHT for Full-Size Freezer (15-17 Cu. Ft.).
Fit class uses buffered needs (running and surge) for this device.
Extended Food Storage
Select Your Model:
Free Tools
The 1000W surge can handle typical compressor startup events in refrigerators, window AC units, and well pumps that fall within momentary draw limits. Sustained loads must stay at or below 500W to avoid shutdown. This is a light-duty unit for essential circuits, not whole-home backup.
This portable station uses LFP chemistry, known for thermal stability in consumer lithium batteries. The 512Wh capacity and 500W continuous rating provide a workable buffer for appliances within spec. Source: EcoFlow RIVER 2 Max User Manual v1.0 (manufacturer documentation).
Keep your Full-Size Freezer (15-17 Cu. Ft.) running with solar โข MPPT: 11โ 50V โข Max: 220W
Official 220W Panel
Adapter required: MC4 -> XT60i.
Smart Value 200W Panel
Adapter required: MC4 -> XT60i.
Smart Value 200W Panel
Adapter required: MC4 -> XT60i.
Yes. The EcoFlow RIVER 2 Max provides 500W running / 1000W surge. The Full-Size Freezer (15-17 Cu. Ft.) needs 200W / 400W (including 25% buffer). That leaves 300W of running headroom and 600W of surge margin.
Approximately 2.2 hours, based on the Full-Size Freezer (15-17 Cu. Ft.)'s 160W draw and the RIVER 2 Max's 512Wh capacity (70% usable after real-world losses).
With 230W allocated to the Full-Size Freezer (15-17 Cu. Ft.), the RIVER 2 Max still has ~10W of margin. These devices could run simultaneously:
Storm Safety: Since the Full-Size Freezer (15-17 Cu. Ft.) is critical for preventing flooding, we recommend testing this setup specifically before the storm season. Ensure the RIVER 2 Max is fully charged to 100% as storms approach.
Compare all 33 generators for the Full-Size Freezer (15-17 Cu. Ft.)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Worst case = Frigidaire FFFU16F2VW (160W running, 320W surge). Running watts derived from OEM kWh/yr via duty-cycle formula; surge estimated at 2.0x (conservative, no OEM LRA published for any freezer in this class).
EcoFlow RIVER 2 Max User Manual v1.0
Similar-output alternatives you can compare side by side.