Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
Yes - RIVER 3 has enough running and surge power for the French Door Refrigerator. Target ~259W running / 518W surge; the generator provides 300W / 600W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
259W required -> 300W available (41W headroom)
Startup peak with safety buffer applied.
518W required -> 600W available (82W headroom)
Alternative startup path with reduced inrush.
233W required -> 600W available (367W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 0.8h
Typical cycling estimate (40% duty): 2.0h
Device profile reference: up to 24h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: LG LMXS28596S Door-in-Door (27.8 cu.ft) (414W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| GE Profile PGD29BYTFS (28.7 cu.ft) | 195W | 390W | Safe | ~0.9h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 195W (derived from 681 kWh/yr at 40% duty cycle). **Surge:** 390W estimated (2x conservative multiplier โ compressor type not explicitly published). **Voltage:** 120V AC. Running watts represent active compressor draw, not the 15A minimum circuit rating on the nameplate. Field note: The GE Profile PGD29BYTFS is a Wi-Fi connected 4-door model. The 195W running draw and 390W surge make it highly compatible with most portable power stations. The real constraint for multi-day outages is battery capacity, not inverter output. Can I keep my GE Profile french door refrigerator running during a power outage? Only if your power source can supply at least 195W continuous and 390W surge at 120V. At ~78W average draw, a 1 kWh battery lasts roughly 13 hours between charges. | |||||
| Samsung RF29DB9900 Bespoke (28.6 cu.ft) | 200W | 400W | Safe | ~0.9h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 200W (derived from 700 kWh/yr at 40% duty cycle). **Surge:** 400W estimated (2x conservative multiplier โ compressor type not explicitly published in electrical specs). **Voltage:** 120V AC. The 700 kWh/yr EnergyGuide rating confirms this is a mid-range draw for a 28.6 cu.ft unit. Field note: The Samsung Bespoke 4-Door Flex is one of the best-selling premium french door refrigerators in the US. Its 200W running draw is well within the range of virtually all portable power stations. Battery capacity โ not output wattage โ is the limiting factor for multi-day backup. Can I run the Samsung Bespoke refrigerator on a portable power station during a blackout? Only if your power source can supply at least 200W continuous and 400W surge at 120V. At ~80W average draw, a 1 kWh battery lasts roughly 12.5 hours between charges. | |||||
| LG LMXS28596S Door-in-Door (27.8 cu.ft) | 207W | 414W | Safe | ~0.8h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 207W (derived from 724 kWh/yr at 40% duty cycle). **Surge:** 414W estimated (2x conservative multiplier โ compressor type not explicitly published in electrical specs). **Voltage:** 120V AC. The highest energy consumption in this comparison at 724 kWh/yr, driven by 27.8 cu.ft capacity and Door-in-Door feature. Field note: The LG Door-in-Door is the highest-draw model in this comparison at 207W running. The InstaView window and Door-in-Door compartment add thermal load from frequent partial opening. Even at worst case, any power station above 500W output can handle this refrigerator โ battery capacity is the real constraint. Can I keep my LG Door-in-Door refrigerator running on battery backup? Only if your power source can supply at least 207W continuous and 414W surge at 120V. At ~83W average draw, a 1 kWh battery lasts roughly 12 hours between charges. | |||||
This unit ranks #2 of 32 compatible generators for this device by buffered margin (Best Fit class).
32 of 33 generators are SAFE+TIGHT for French Door Refrigerator.
Fit class uses buffered needs (running and surge) for this device.
72-Hour Power Outage
Select Your Model:
Free Tools
The 600W surge rating can handle typical startup loads from small compressor-driven appliances like mini fridges and air tools. It can support motor-driven devices that require momentary inrush current during ignition. At 245Wh total capacity, expect limited runtime on continuous loads near the 300W ceiling.
LFP chemistry provides stable operation under load cycling. The unit accommodates brief inrush events up to 600W for equipment startup. Source: EcoFlow RIVER 3 User Manual v1.0 (manufacturer documentation).
Keep your French Door Refrigerator running with solar โข MPPT: 11โ 30V โข Max: 110W
Official 110W Panel
Adapter required: MC4 -> XT60i.
Smart Value 100W Panel
Adapter required: Goal Zero proprietary -> XT60i adapter required.
Smart Value 100W Panel
Adapter required: Jackery proprietary -> XT60i adapter required.
Yes. The EcoFlow RIVER 3 provides 300W running / 600W surge. The French Door Refrigerator needs 259W / 518W (including 25% buffer). That leaves 41W of running headroom and 82W of surge margin.
Approximately 0.8 hours, based on the French Door Refrigerator's 207W draw and the RIVER 3's 245Wh capacity (70% usable after real-world losses).
With 25W allocated to the French Door Refrigerator, the RIVER 3 still has ~8W of margin. These devices could run simultaneously:
Efficiency Hack: Large appliances like the French Door Refrigerator cycle on and off. To maximize the 0.8 hours of runtime, try to minimize how often you open the device or introduce heat loads.
Compare all 33 generators for the French Door Refrigerator
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Worst case = LG LMXS28596S (207W running, 414W surge). Formula: avg_w = kWh_year ร 1000 / 8760; running_w = ceil(avg_w / 0.40); surge_w = ceil(running_w ร 2.0).
EcoFlow RIVER 3 User Manual (2024-09-11)