Skip to main content
GeneratorChecker

Yes, the Yeti Pro 4000 can run a Dehumidifier (70 Pint)

This pairing clears the safety headroom. Required ~1075W running and 4169W surge; the Yeti Pro 4000 is rated 3600W / 7200W.

Power Margin Analysis

3600W / 7200W Capacity
Running 2525W headroom
1075W required
Surge 3031W headroom
4169W required

Decision Gate Waterfall

Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.

1

Voltage Gate

PASS

Device output type must match generator output.

120V required -> 120V available

2

Running Gate

PASS

Continuous draw with safety buffer applied.

1,075W required -> 3,600W available (2,525W headroom)

Required 1,075W required
Available 3,600W
3

Surge Gate

PASS

Startup peak with safety buffer applied.

4,169W required -> 7,200W available (3,031W headroom)

Required 4,169W required
Available 7,200W
3b

With Soft-Start

PASS

Alternative startup path with reduced inrush.

1,876W required -> 7,200W available (5,324W headroom)

Required 1,876W
Available 7,200W
4

Runtime Insight

INFO

Runtime context only. It does not change the electrical compatibility verdict.

Continuous estimate: 3.3h

Device profile reference: up to 24h per day.

Power bars show required versus available output for each gate.

View full compatibility report

Decision Snapshot

Quick compatibility, required headroom, and model-specific context at a glance.

โšก
3600W
Running Power
๐Ÿ”‹
3993.6Wh
Capacity
โฑ๏ธ
~3.3h
Est. Runtime
โ˜€๏ธ
3000W
Solar Input

Quick Compatibility Check

  1. 1 Running headroom: target 1075W; generator provides 3600W.
  2. 2 Surge headroom: target 4169W; generator provides 7200W.
  3. 3 Tip: leave headroom for startup spikes and warm conditions.

Model-Specific Results

3 of 3 models are SAFE or TIGHT. Most demanding model: Midea EasyDry MDP70SR71 (70 Pint) (3,335W surge).

Model Running Surge Verdict Runtime Source
Midea EasyDry MDP70SR71 (70 Pint) 690W 3,335W Safe ~4.1h OEM Manual
Show expert analysis

Technical: **Voltage:** 120V AC required. **Running load:** 690W. **Surge:** 3335W at startup (compressor-driven). Only power stations with inverter surge capacity โ‰ฅ3335W and continuous output โ‰ฅ690W are candidates.

Field note: Verify the power station's surge window duration. Short-duration surge ratings may not accommodate refrigerant compressor startup transients reliably.

Can I run this dehumidifier on a portable power station overnight?

Only if your power source can supply at least 690W continuous and 3335W surge at 120V. It depends on the station's surge capacity and battery size.

Midea EasyDry MDP70PR71 with Pump (70 Pint) 690W 3,335W Safe ~4.1h OEM Manual
Show expert analysis

Technical: **Running load:** 690 W. **Surge demand:** 3,335 W at compressor start. Requires 120V AC output. Power station must deliver the full surge envelope without tripping overcurrent protection.

Field note: Ensure your power station's inverter can handle the 3,335 W surge without shutdown. Verify outlet capacity exceeds continuous draw.

Can I run this dehumidifier on a portable power station?

Only if your power source can supply at least 690W continuous and 3335W surge at 120V. Most portable units cannot meet the surge requirement.

Haier HEN70ETF (70 Pint) 860W 2,580W Safe ~3.3h OEM Verified
Show expert analysis

Technical: **Running load:** 860W. **Surge:** 2580W at startup. Requires 120V AC output. Power station must sustain 860W continuous and handle 2580W compressor inrush without tripping.

Field note: Size the power station to at least 125% of running load (1075W minimum output) to avoid nuisance shutdowns during concurrent household draw.

Can I run this dehumidifier overnight on a portable power station?

Only if your power source can supply at least 860W continuous and 2580W surge at 120V. Most portable units lack sufficient capacity for full-day basement moisture control.

How This Pairing Performs Across Our Database

This unit ranks #13 of 17 compatible generators for this device by buffered margin (Overkill class).

How Dehumidifier (70 Pint) Performs Across 33 Tested Generators

17 of 33 generators are SAFE+TIGHT for Dehumidifier (70 Pint).

17 Safe+Tight
Safe 12 (36%)
Tight 5 (15%)
Soft Start 6 (18%)
Fail 10 (30%)

Power Comparison: Goal Zero Yeti Pro 4000 vs Top Alternatives for Dehumidifier (70 Pint)

Fit class uses buffered needs (running and surge) for this device.

Specs & Surge Analysis

Dehumidifier (70 Pint)
Heating & Cooling

Dehumidifier (70 Pint)

Basement Moisture Control

860W
Running
3335W
Surge
120V
Required

True Surgeโ„ข Analysis

Safety Buffer: +25%
Running Power Usage 30% Utilization
1075W required 3600W Capacity
2525W headroom
Surge/Startup Peak 58% Utilization
4169W required 7200W Capacity
3031W headroom
Voltage Match 120V โ†” 120V โœ“
โš ๏ธ Before You Buy: Connection Check
Installation warning

These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.

Generator Insights

The 7200 W surge can handle typical compressor-based appliances like well pumps, refrigerators, and air conditioning startup events on 120V circuits. The 3600 W continuous rating supports sustained operation once inrush currents settle, making this unit a strong option for heavy 120V backup loads.

This unit uses LFP chemistry and draws from manufacturer documentation for its output specifications. The 7200 W surge rating reflects the inverter's transient capacity, not a thermal or safety certification. Source: Goal Zero Yeti Pro 4000 User Manual (Output Specifications) (manufacturer documentation).

Extend Runtime with Solar

Keep your Dehumidifier (70 Pint) running with solar โ€ข MPPT: 13.3โ€“ 145V โ€ข Max: 3000W

Goal Zero undefined Official

Goal Zero

200W Panel

1 Hour Sun =
+0.2h per sun hour
Plug & Play
Full in ~28.5h
Anker undefined Smart Value

Anker

400W Panel

1 Hour Sun =
+0.3h per sun hour
MC4 -> HPP+
Full in ~14.3h

Adapter required: MC4 -> HPP+.

EcoFlow undefined Smart Value

EcoFlow

400W Panel

1 Hour Sun =
+0.3h per sun hour
MC4 -> HPP+
Full in ~14.3h

Adapter required: MC4 -> HPP+.

Technical Analysis

Spec-Based โ€ข No Guarantees

Technical Breakdown

Running load: 860 W continuous. Surge demand: 3335 W at compressor startup. Voltage: 120 V AC required. Power station must handle the surge margin and sustain the load for the intended duration.

Expected Behavior

Estimated runtime: ~3.3h. Operates 24 hours per day drawing approximately 20640 Wh daily. Compressor cycles cause brief high-current transients during startup then settles to steady draw.

Field Note

Verify the power station inverter rating exceeds 3335 W surge capacity. Undersized units will trip during compressor kick-in.

Frequently Asked Questions

Can the Goal Zero Yeti Pro 4000 power a Dehumidifier (70 Pint)?

Yes. The Goal Zero Yeti Pro 4000 provides 3600W running / 7200W surge. The Dehumidifier (70 Pint) needs 1075W / 4169W (including 25% buffer). That leaves 2525W of running headroom and 3031W of surge margin.

How long will the Yeti Pro 4000 run a Dehumidifier (70 Pint)?

Approximately 3.3 hours, based on the Dehumidifier (70 Pint)'s 860W draw and the Yeti Pro 4000's 3993.6Wh capacity (70% usable after real-world losses).

What Else Can You Run?

With 975W allocated to the Dehumidifier (70 Pint), the Yeti Pro 4000 still has ~1045W of margin. These devices could run simultaneously:

๐Ÿ“บ
55' LED TV
80W
๐Ÿ”ฅ
Space Heater (Eco)
750W
๐Ÿ’ก
LED Lamp
10W
๐ŸŒ€
Box Fan (Medium)
60W
๐ŸŒฌ๏ธ
Nebulizer
60W
๐Ÿ“ก
Wifi Router
15W

Power Tip: To get the most out of your Yeti Pro 4000, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.

Compare all 33 generators for the Dehumidifier (70 Pint)

Ranked by budget, runtime, and overall compatibility.

See full ranking
Technical Sourcing & Verification
ID: goal-zero-yeti-pro-4000-dehumidifier-70pint
๐Ÿ›๏ธ Device Data Source
Engineering Est. Safety Factor Applied

Derived from variant list (max of variants). Running worst case = Haier HEN70ETF (860W). Surge worst case = Midea EasyDry MDP70SR71 (3335W).

โšก Generator Specs Source
OEM Verified

Goal Zero Yeti PRO 4000 (120V) User Guide

Methodology informed by US Department of Energy (DOE) & EIA references where applicable. Our methodology โ†’

Compare these models

Similar-output alternatives you can compare side by side.