Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V/240V available
3 of 3 models are compatible with this generator.
Jump to model-specific results โSame decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V/240V available
Continuous draw with safety buffer applied.
863W to 1,075W required -> 3,800W available (2,725W to 2,937W headroom)
Startup peak with safety buffer applied.
3,225W to 4,169W required -> 3,800W available (575W headroom on lighter models)
Alternative startup path with reduced inrush.
1,876W required -> 3,800W available (1,924W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 3.8h
Device profile reference: up to 24h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Midea EasyDry MDP70SR71 (70 Pint) (3,335W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Midea EasyDry MDP70SR71 (70 Pint) | 690W | 3,335W | Tight | ~4.7h | OEM Manual |
Show expert analysisTechnical: **Voltage:** 120V AC required. **Running load:** 690W. **Surge:** 3335W at startup (compressor-driven). Only power stations with inverter surge capacity โฅ3335W and continuous output โฅ690W are candidates. Field note: Verify the power station's surge window duration. Short-duration surge ratings may not accommodate refrigerant compressor startup transients reliably. Can I run this dehumidifier on a portable power station overnight? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. It depends on the station's surge capacity and battery size. | |||||
| Midea EasyDry MDP70PR71 with Pump (70 Pint) | 690W | 3,335W | Tight | ~4.7h | OEM Manual |
Show expert analysisTechnical: **Running load:** 690 W. **Surge demand:** 3,335 W at compressor start. Requires 120V AC output. Power station must deliver the full surge envelope without tripping overcurrent protection. Field note: Ensure your power station's inverter can handle the 3,335 W surge without shutdown. Verify outlet capacity exceeds continuous draw. Can I run this dehumidifier on a portable power station? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. Most portable units cannot meet the surge requirement. | |||||
| Haier HEN70ETF (70 Pint) | 860W | 2,580W | Safe | ~3.8h | OEM Verified |
Show expert analysisTechnical: **Running load:** 860W. **Surge:** 2580W at startup. Requires 120V AC output. Power station must sustain 860W continuous and handle 2580W compressor inrush without tripping. Field note: Size the power station to at least 125% of running load (1075W minimum output) to avoid nuisance shutdowns during concurrent household draw. Can I run this dehumidifier overnight on a portable power station? Only if your power source can supply at least 860W continuous and 2580W surge at 120V. Most portable units lack sufficient capacity for full-day basement moisture control. | |||||
This unit ranks #8 of 17 compatible generators for this device by buffered margin (Overkill class).
17 of 33 generators are SAFE+TIGHT for Dehumidifier (70 Pint).
Fit class uses buffered needs (running and surge) for this device.
Basement Moisture Control
Select Your Model:
These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.
Free Tools
At 3800W continuous, the SuperBase V4600 handles most residential loads comfortably. The conservative surge rating (no hardware surge above continuous) means high-inrush devices like air compressors and well pumps may trigger protection cutoffs โ always check surge requirements. The 4608Wh base capacity provides 12+ hours for moderate loads, and the modular B4600 satellite system scales to 23kWh for multi-day outages. Solar input accepts up to 1500W (150V ร 10A) via XT90, though the single-port design limits parallel panel configurations.
The SuperBase V4600 uses LiFePO4 chemistry rated for 3,000+ cycles. The GridFlow 2.0 system provides 1ms UPS switchover, making it suitable for sensitive medical and computing equipment. The 120V/240V selective output supports both standard and high-voltage appliances. Source: Zendure official US product page (manufacturer documentation).
Keep your Dehumidifier (70 Pint) running with solar โข MPPT: 12โ 150V โข Max: 1500W
Smart Value 400W Panel
Adapter required: MC4 -> XT90.
Smart Value 400W Panel
Adapter required: MC4 -> XT90.
It depends on the model. 3 of 3 Dehumidifier (70 Pint) models are compatible with the Zendure SuperBase V4600. See the model-specific results table for exact verdicts per model.
It depends on the model. Compatible models run approximately 3.8โ4.7 hours on the Zendure SuperBase V4600. 0 of 3 models are not compatible. See the model-specific results for details.
With 960W allocated to the Dehumidifier (70 Pint), the Zendure SuperBase V4600 still has ~1220W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your Zendure SuperBase V4600, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Dehumidifier (70 Pint)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Haier HEN70ETF (860W). Surge worst case = Midea EasyDry MDP70SR71 (3335W).
Zendure SuperBase V Official Product Page (US) โ full specifications
Similar-output alternatives you can compare side by side.