Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V/240V available
3 of 3 models are compatible with this generator.
Jump to model-specific results โSame decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V/240V available
Continuous draw with safety buffer applied.
1,058W to 1,297W required -> 3,800W available (2,503W to 2,742W headroom)
Startup peak with safety buffer applied.
3,042W to 3,889W required -> 3,800W available (758W headroom on lighter models)
Alternative startup path with reduced inrush.
1,750W required -> 3,800W available (2,050W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 2.9h
Device profile reference: up to 2h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Wayne CDU800 (1/2 HP) (3,381W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Zoeller M98 Flow-Mate (1/2 HP) | 1,081W | 3,243W | Safe | ~3.0h | NEC Standard |
Show expert analysisTechnical: **Running load:** 1,081W (115V x 9.4A OEM rated). **Surge:** 3,243W at motor startup (3x NEC estimate). **Voltage:** 120V AC. The cast iron PSC motor draws heavy inrush current on every pump cycle. Field note: The Zoeller M98 is the industry reference in cast iron sump pumps. Its PSC motor has no built-in soft-start โ the full inrush hits the power station instantly. An external soft-start device can reduce this surge, but size the inverter for the full 3,243W if running without one. Can I run a Zoeller M98 sump pump on a portable power station during a flood? Only if your power source can supply at least 1,081W continuous and 3,243W surge at 120V. The PSC motor creates a hard startup spike that will trip undersized inverters. | |||||
| Wayne CDU800 (1/2 HP) | 1,127W | 3,381W | Tight | ~2.9h | NEC Standard |
Show expert analysisTechnical: **Running load:** 1,127W (NEC 430.248 rated). **Surge:** 3,381W at motor startup (3x NEC estimate). **Voltage:** 120V AC. The coated steel PSC motor draws the highest inrush in this class due to its conservative NEC-rated amperage. Field note: The Wayne CDU800 is the Home Depot best-seller for suburban basements. Without OEM amperage data, specs are derived from NEC tables โ the actual draw may be slightly lower, but sizing to NEC ensures safe headroom. Can I keep my Wayne sump pump running on battery backup during a storm? Only if your power source can supply at least 1,127W continuous and 3,381W surge at 120V. The motor startup surge is the critical factor โ most small power stations cannot handle it. | |||||
| Liberty Pumps 287 VMF (1/2 HP) | 920W | 2,645W | Safe | ~3.5h | OEM Manual |
Show expert analysisTechnical: **Running load:** 920W (115V x 8.0A OEM rated). **Surge:** 2,645W at motor startup (115V x 23A LRA, OEM verified). **Voltage:** 120V AC. The 3450 RPM PSC motor with OEM-documented LRA provides the most precise surge data in this class. Field note: The Liberty 287 is the plumber's choice and the most battery-friendly 1/2 HP sump pump in this comparison. With OEM-verified LRA data, the 2,645W surge is a confirmed number โ not an estimate. A 3,000W power station can handle this reliably. Is the Liberty 287 easier to run on a power station than other sump pumps? Only if your power source can supply at least 920W continuous and 2,645W surge at 120V. Its OEM-documented 23A locked rotor current is lower than NEC estimates for competing 1/2 HP pumps, making it more generator-friendly. | |||||
This unit ranks #8 of 17 compatible generators for this device by buffered margin (Overkill class).
17 of 33 generators are SAFE+TIGHT for Sump Pump (1/2 HP).
Fit class uses buffered needs (running and surge) for this device.
Storm Flood Prevention
Select Your Model:
These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.
Free Tools
At 3800W continuous, the SuperBase V4600 handles most residential loads comfortably. The conservative surge rating (no hardware surge above continuous) means high-inrush devices like air compressors and well pumps may trigger protection cutoffs โ always check surge requirements. The 4608Wh base capacity provides 12+ hours for moderate loads, and the modular B4600 satellite system scales to 23kWh for multi-day outages. Solar input accepts up to 1500W (150V ร 10A) via XT90, though the single-port design limits parallel panel configurations.
The SuperBase V4600 uses LiFePO4 chemistry rated for 3,000+ cycles. The GridFlow 2.0 system provides 1ms UPS switchover, making it suitable for sensitive medical and computing equipment. The 120V/240V selective output supports both standard and high-voltage appliances. Source: Zendure official US product page (manufacturer documentation).
Keep your Sump Pump (1/2 HP) running with solar โข MPPT: 12โ 150V โข Max: 1500W
Smart Value 400W Panel
Adapter required: MC4 -> XT90.
Smart Value 400W Panel
Adapter required: MC4 -> XT90.
It depends on the model. 3 of 3 Sump Pump (1/2 HP) models are compatible with the Zendure SuperBase V4600. See the model-specific results table for exact verdicts per model.
It depends on the model. Compatible models run approximately 2.9โ3.5 hours on the Zendure SuperBase V4600. 0 of 3 models are not compatible. See the model-specific results for details.
With 970W allocated to the Sump Pump (1/2 HP), the Zendure SuperBase V4600 still has ~943W of margin. These devices could run simultaneously:
Storm Safety: Since the Sump Pump (1/2 HP) is critical for preventing flooding, we recommend testing this setup specifically before the storm season. Ensure the Zendure SuperBase V4600 is fully charged to 100% as storms approach.
Compare all 33 generators for the Sump Pump (1/2 HP)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Worst case = Wayne CDU800 (1127W running, 3381W surge).
Zendure SuperBase V Official Product Page (US) โ full specifications
Similar-output alternatives you can compare side by side.