Skip to main content
GeneratorChecker

Can the SOLIX C800 Plus Run a Dehumidifier (70 Pint)? It Depends on Your Model

0 of 3 models are compatible with this generator.

Jump to model-specific results โ†“

Power Margin Analysis

1200W / 1600W Capacity
Running 125W to 337W headroom by model
863W to 1075W required
Surge 1625W to 2569W short by model
3225W to 4169W required

Decision Gate Waterfall

Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.

1

Voltage Gate

PASS

Device output type must match generator output.

120V required -> 120V available

2

Running Gate

PASS

Continuous draw with safety buffer applied.

863W to 1,075W required -> 1,200W available (125W to 337W headroom)

Required 863W to 1,075W required
Available 1,200W
3

Surge Gate

FAIL

Startup peak with safety buffer applied.

3,225W to 4,169W required -> 1,600W available (1,625W to 2,569W short)

Required 3,225W to 4,169W required
Available 1,600W
3b

With Soft-Start

FAIL

Alternative startup path with reduced inrush.

1,876W required -> 1,600W available (276W short)

Required 1,876W
Available 1,600W
4

Runtime Insight

INFO

Runtime context only. It does not change the electrical compatibility verdict.

Continuous estimate: 0.6h

Device profile reference: up to 24h per day.

Power bars show required versus available output for each gate.

See soft-start options

Decision Snapshot

Quick compatibility, required headroom, and model-specific context at a glance.

โšก
1200W
Running Power
๐Ÿ”‹
768Wh
Capacity
โฑ๏ธ
~0.6h
Est. Runtime
โ˜€๏ธ
300W
Solar Input

Quick Compatibility Check

  1. 1 0 of 3 models are compatible with the SOLIX C800 Plus.
  2. 2 Model requirements range from 690W to 860W running watts.
  3. 3 See the model-specific results table for per-model verdicts.

What To Do Instead

  1. 1 Install a soft-starter: Reduces the Dehumidifier (70 Pint)'s startup surge from 3335W to ~1501W, within the SOLIX C800 Plus's 1600W surge capacity.
  2. 2 Or size up: Without a soft-starter, you need at least 4169W surge capacity (3335W ร— 25% buffer).
  3. 3 No-install alternative: The Explorer 2000 Plus (6000W surge) handles the full 3335W startup natively โ€” no soft-starter needed.

Model-Specific Results

0 of 3 models are SAFE or TIGHT. Most demanding model: Midea EasyDry MDP70SR71 (70 Pint) (3,335W surge).

Model Running Surge Verdict Runtime Source
Midea EasyDry MDP70SR71 (70 Pint) 690W 3,335W Fail โ€” OEM Manual
Show expert analysis

Technical: **Voltage:** 120V AC required. **Running load:** 690W. **Surge:** 3335W at startup (compressor-driven). Only power stations with inverter surge capacity โ‰ฅ3335W and continuous output โ‰ฅ690W are candidates.

Field note: Verify the power station's surge window duration. Short-duration surge ratings may not accommodate refrigerant compressor startup transients reliably.

Can I run this dehumidifier on a portable power station overnight?

Only if your power source can supply at least 690W continuous and 3335W surge at 120V. It depends on the station's surge capacity and battery size.

Midea EasyDry MDP70PR71 with Pump (70 Pint) 690W 3,335W Fail โ€” OEM Manual
Show expert analysis

Technical: **Running load:** 690 W. **Surge demand:** 3,335 W at compressor start. Requires 120V AC output. Power station must deliver the full surge envelope without tripping overcurrent protection.

Field note: Ensure your power station's inverter can handle the 3,335 W surge without shutdown. Verify outlet capacity exceeds continuous draw.

Can I run this dehumidifier on a portable power station?

Only if your power source can supply at least 690W continuous and 3335W surge at 120V. Most portable units cannot meet the surge requirement.

Haier HEN70ETF (70 Pint) 860W 2,580W Soft Start ~0.6h OEM Verified
Show expert analysis

Technical: **Running load:** 860W. **Surge:** 2580W at startup. Requires 120V AC output. Power station must sustain 860W continuous and handle 2580W compressor inrush without tripping.

Field note: Size the power station to at least 125% of running load (1075W minimum output) to avoid nuisance shutdowns during concurrent household draw.

Can I run this dehumidifier overnight on a portable power station?

Only if your power source can supply at least 860W continuous and 2580W surge at 120V. Most portable units lack sufficient capacity for full-day basement moisture control.

How This Pairing Performs Across Our Database

This unit is outside the compatible set; 17 of 33 generators pass SAFE/TIGHT for this device.

How Dehumidifier (70 Pint) Performs Across 33 Tested Generators

17 of 33 generators are SAFE+TIGHT for Dehumidifier (70 Pint).

17 Safe+Tight
Safe 12 (36%)
Tight 5 (15%)
Soft Start 6 (18%)
Fail 10 (30%)

Power Comparison: Anker SOLIX C800 Plus vs Top Alternatives for Dehumidifier (70 Pint)

Fit class uses buffered needs (running and surge) for this device.

Specs & Surge Analysis

Dehumidifier (70 Pint)
Heating & Cooling

Dehumidifier (70 Pint)

Basement Moisture Control

860W
Running
3335W
Surge
120V
Required

True Surgeโ„ข Analysis

Safety Buffer: +25%
Running Power Usage 72% to 90% Utilization
863W to 1075W required 1200W Capacity
125W to 337W headroom by model
Surge/Startup Peak 202% to 261% Utilization
3225W to 4169W required 1600W Capacity
1625W to 2569W short by model
Voltage Match 120V โ†” 120V โœ“

Startup Surge Visual

โšก Soft-Starter Required

The Dehumidifier (70 Pint)'s startup surge (3335W) exceeds this generator's capacity. A soft-starter can reduce inrush current by ~55%, bringing surge down to approximately 1501W.

Original Surge: 3335W
โ†’
With Soft-Start: ~1501W
โš ๏ธ Before You Buy: Connection Check
Installation warning

These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.

No-Install Alternatives to SOLIX C800 Plus

Prefer not to install a soft starter on Dehumidifier (70 Pint)? These generators can start this load natively.

Best Value Explorer 2000 Plus

Explorer 2000 Plus

3000W โ€ข 2042Wh

Runtime at your load
~1.7h
Capacity Fit Expandable to 12000Wh

Lowest capacity that still clears surge + running load.

Max Runtime Delta Pro

Delta Pro

3600W โ€ข 3600Wh

Runtime at your load
~2.9h
Longest Runtime Expandable to 25000Wh

Expandable to 25000Wh.

Generator Insights

The 1600W surge rating can support startup sequences for refrigerator compressors, well pumps, and similar inductive motor loads that draw 25 to 33 percent over running current during initial engagement. Once running, the 1200W continuous output can handle typical kitchen appliances, electronics, and power tools within rated limits. This combination addresses both inrush events and sustained runtime needs in backup scenarios.

This unit uses LFP chemistry, a battery architecture chosen for thermal stability in consumer power stations. The 768Wh capacity and 1200W continuous output allow sustained operation without thermal stress under typical residential loads. Source: Anker SOLIX C800 Plus Tech Specs (manufacturer documentation).

Extend Runtime with Solar

Keep your Dehumidifier (70 Pint) running with solar โ€ข MPPT: 11โ€“ 60V โ€ข Max: 300W

Anker undefined Official

Anker

100W Panel

1 Hour Sun =
+0.1h per sun hour
MC4 -> XT60
Full in ~11h

Adapter required: MC4 -> XT60.

Bluetti undefined Smart Value

Bluetti

200W Panel

1 Hour Sun =
+0.2h per sun hour
MC4 -> XT60
Full in ~5.5h

Adapter required: MC4 -> XT60.

BougeRV undefined Smart Value

BougeRV

200W Panel

1 Hour Sun =
+0.2h per sun hour
MC4 -> XT60
Full in ~5.5h

Adapter required: MC4 -> XT60.

Technical Analysis

Spec-Based โ€ข No Guarantees

Technical Breakdown

Running load: 860 W continuous. Surge demand: 3335 W at compressor startup. Voltage: 120 V AC required. Power station must handle the surge margin and sustain the load for the intended duration.

Expected Behavior

Estimated runtime: ~0.6h. Operates 24 hours per day drawing approximately 20640 Wh daily. Compressor cycles cause brief high-current transients during startup then settles to steady draw.

Field Note

Verify the power station inverter rating exceeds 3335 W surge capacity. Undersized units will trip during compressor kick-in.

Frequently Asked Questions

Can the Anker SOLIX C800 Plus power a Dehumidifier (70 Pint)?

It depends on the model. 0 of 3 Dehumidifier (70 Pint) models are compatible with the Anker SOLIX C800 Plus. See the model-specific results table for exact verdicts per model.

How long will the SOLIX C800 Plus run a Dehumidifier (70 Pint)?

It depends on the model. Compatible models run approximately 0.6โ€“0.6 hours on the SOLIX C800 Plus. 2 of 3 models are not compatible. See the model-specific results for details.

Power Tip: To get the most out of your SOLIX C800 Plus, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.

Compare all 33 generators for the Dehumidifier (70 Pint)

Ranked by budget, runtime, and overall compatibility.

See full ranking
Technical Sourcing & Verification
ID: anker-solix-c800-plus-dehumidifier-70pint
๐Ÿ›๏ธ Device Data Source
Engineering Est. Safety Factor Applied

Derived from variant list (max of variants). Running worst case = Haier HEN70ETF (860W). Surge worst case = Midea EasyDry MDP70SR71 (3335W).

โšก Generator Specs Source
OEM Verified

Anker SOLIX C800 Plus User Manual (EN-US)

Methodology informed by US Department of Energy (DOE) & EIA references where applicable. Our methodology โ†’

Compare these models

Similar-output alternatives you can compare side by side.