Skip to main content
GeneratorChecker

Can the DELTA 2 Run a Dehumidifier (70 Pint)? It Depends on Your Model

1 of 3 models are compatible with this generator.

Jump to model-specific results โ†“

Power Margin Analysis

1800W / 2700W Capacity
Running 725W to 937W headroom by model
863W to 1075W required
Surge 525W to 1469W short by model
3225W to 4169W required

Decision Gate Waterfall

Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.

1

Voltage Gate

PASS

Device output type must match generator output.

120V required -> 120V available

2

Running Gate

PASS

Continuous draw with safety buffer applied.

863W to 1,075W required -> 1,800W available (725W to 937W headroom)

Required 863W to 1,075W required
Available 1,800W
3

Surge Gate

FAIL

Startup peak with safety buffer applied.

3,225W to 4,169W required -> 2,700W available (525W to 1,469W short)

Required 3,225W to 4,169W required
Available 2,700W
3b

With Soft-Start

PASS

Alternative startup path with reduced inrush.

1,876W required -> 2,700W available (824W headroom)

Required 1,876W
Available 2,700W
4

Runtime Insight

INFO

Runtime context only. It does not change the electrical compatibility verdict.

Continuous estimate: 0.8h

Device profile reference: up to 24h per day.

Power bars show required versus available output for each gate.

View full compatibility report

Decision Snapshot

Quick compatibility, required headroom, and model-specific context at a glance.

โšก
1800W
Running Power
๐Ÿ”‹
1024Wh
Capacity
โฑ๏ธ
~0.8h
Est. Runtime
โ˜€๏ธ
500W
Solar Input

Quick Compatibility Check

  1. 1 1 of 3 models are compatible with the DELTA 2.
  2. 2 Model requirements range from 690W to 860W running watts.
  3. 3 See the model-specific results table for per-model verdicts.

Model-Specific Results

1 of 3 models are SAFE or TIGHT. Most demanding model: Midea EasyDry MDP70SR71 (70 Pint) (3,335W surge).

Model Running Surge Verdict Runtime Source
Midea EasyDry MDP70SR71 (70 Pint) 690W 3,335W Soft Start ~1.0h OEM Manual
Show expert analysis

Technical: **Voltage:** 120V AC required. **Running load:** 690W. **Surge:** 3335W at startup (compressor-driven). Only power stations with inverter surge capacity โ‰ฅ3335W and continuous output โ‰ฅ690W are candidates.

Field note: Verify the power station's surge window duration. Short-duration surge ratings may not accommodate refrigerant compressor startup transients reliably.

Can I run this dehumidifier on a portable power station overnight?

Only if your power source can supply at least 690W continuous and 3335W surge at 120V. It depends on the station's surge capacity and battery size.

Midea EasyDry MDP70PR71 with Pump (70 Pint) 690W 3,335W Soft Start ~1.0h OEM Manual
Show expert analysis

Technical: **Running load:** 690 W. **Surge demand:** 3,335 W at compressor start. Requires 120V AC output. Power station must deliver the full surge envelope without tripping overcurrent protection.

Field note: Ensure your power station's inverter can handle the 3,335 W surge without shutdown. Verify outlet capacity exceeds continuous draw.

Can I run this dehumidifier on a portable power station?

Only if your power source can supply at least 690W continuous and 3335W surge at 120V. Most portable units cannot meet the surge requirement.

Haier HEN70ETF (70 Pint) 860W 2,580W Tight ~0.8h OEM Verified
Show expert analysis

Technical: **Running load:** 860W. **Surge:** 2580W at startup. Requires 120V AC output. Power station must sustain 860W continuous and handle 2580W compressor inrush without tripping.

Field note: Size the power station to at least 125% of running load (1075W minimum output) to avoid nuisance shutdowns during concurrent household draw.

Can I run this dehumidifier overnight on a portable power station?

Only if your power source can supply at least 860W continuous and 2580W surge at 120V. Most portable units lack sufficient capacity for full-day basement moisture control.

How This Pairing Performs Across Our Database

This unit is borderline without mitigation; 17 of 33 generators meet SAFE/TIGHT margins for this device.

How Dehumidifier (70 Pint) Performs Across 33 Tested Generators

17 of 33 generators are SAFE+TIGHT for Dehumidifier (70 Pint).

17 Safe+Tight
Safe 12 (36%)
Tight 5 (15%)
Soft Start 6 (18%)
Fail 10 (30%)

Power Comparison: EcoFlow DELTA 2 vs Top Alternatives for Dehumidifier (70 Pint)

Fit class uses buffered needs (running and surge) for this device.

Specs & Surge Analysis

Dehumidifier (70 Pint)
Heating & Cooling

Dehumidifier (70 Pint)

Basement Moisture Control

860W
Running
3335W
Surge
120V
Required

True Surgeโ„ข Analysis

Safety Buffer: +25%
Running Power Usage 48% to 60% Utilization
863W to 1075W required 1800W Capacity
725W to 937W headroom by model
Surge/Startup Peak 119% to 154% Utilization
3225W to 4169W required 2700W Capacity
525W to 1469W short by model
Voltage Match 120V โ†” 120V โœ“

Startup Surge Visual

โš ๏ธ Before You Buy: Connection Check
Installation warning

These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.

Generator Insights

The 2700W surge rating can support typical motor-driven appliances during startup, including residential refrigerators, sump pumps, and air compressor loads. The 1800W running capacity can handle simultaneous operation of multiple mid-range devices. This configuration addresses intermittent high-draw scenarios common in backup power applications.

LFP chemistry provides inherent thermal stability advantages over conventional lithium-ion chemistries. The 1024Wh capacity and dual output ratings reflect design margins for sustained and transient loads. Source: EcoFlow DELTA 2 User Manual v1.0 (manufacturer documentation).

Extend Runtime with Solar

Keep your Dehumidifier (70 Pint) running with solar โ€ข MPPT: 11โ€“ 60V โ€ข Max: 500W

EcoFlow undefined Official

EcoFlow

400W Panel

1 Hour Sun =
+0.3h per sun hour
MC4 -> XT60i
Full in ~3.7h

Adapter required: MC4 -> XT60i.

Bluetti undefined Smart Value

Bluetti

350W Panel

1 Hour Sun =
+0.3h per sun hour
MC4 -> XT60i
Full in ~4.2h

Adapter required: MC4 -> XT60i.

Bluetti undefined Smart Value

Bluetti

200W Panel

1 Hour Sun =
+0.2h per sun hour
MC4 -> XT60i
Full in ~7.3h

Adapter required: MC4 -> XT60i.

Technical Analysis

Spec-Based โ€ข No Guarantees

Technical Breakdown

Running load: 860 W continuous. Surge demand: 3335 W at compressor startup. Voltage: 120 V AC required. Power station must handle the surge margin and sustain the load for the intended duration.

Expected Behavior

Estimated runtime: ~0.8h. Operates 24 hours per day drawing approximately 20640 Wh daily. Compressor cycles cause brief high-current transients during startup then settles to steady draw.

Field Note

Verify the power station inverter rating exceeds 3335 W surge capacity. Undersized units will trip during compressor kick-in.

Frequently Asked Questions

Can the EcoFlow DELTA 2 power a Dehumidifier (70 Pint)?

It depends on the model. 1 of 3 Dehumidifier (70 Pint) models are compatible with the EcoFlow DELTA 2. See the model-specific results table for exact verdicts per model.

How long will the DELTA 2 run a Dehumidifier (70 Pint)?

It depends on the model. Compatible models run approximately 0.8โ€“1.0 hours on the DELTA 2. 0 of 3 models are not compatible. See the model-specific results for details.

What Else Can You Run?

With 470W allocated to the Dehumidifier (70 Pint), the DELTA 2 still has ~110W of margin. These devices could run simultaneously:

๐Ÿ“บ
55' LED TV
80W
๐ŸŒ€
Box Fan (Medium)
60W
๐Ÿ’ก
LED Lamp
10W
๐Ÿ–ฅ๏ธ
24' Monitor
30W
๐ŸŽฎ
Gaming Laptop
230W
๐ŸŒฌ๏ธ
Nebulizer
60W

Power Tip: To get the most out of your DELTA 2, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.

Compare all 33 generators for the Dehumidifier (70 Pint)

Ranked by budget, runtime, and overall compatibility.

See full ranking
Technical Sourcing & Verification
ID: ecoflow-delta-2-dehumidifier-70pint
๐Ÿ›๏ธ Device Data Source
Engineering Est. Safety Factor Applied

Derived from variant list (max of variants). Running worst case = Haier HEN70ETF (860W). Surge worst case = Midea EasyDry MDP70SR71 (3335W).

โšก Generator Specs Source
OEM Verified

EcoFlow DELTA 2 User Manual v1.0

Methodology informed by US Department of Energy (DOE) & EIA references where applicable. Our methodology โ†’

Compare these models

Similar-output alternatives you can compare side by side.