Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
This pairing clears the safety headroom. Required ~888W running and 2513W surge; the DELTA 3 Plus is rated 1800W / 3600W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
888W required -> 1,800W available (912W headroom)
Startup peak with safety buffer applied.
2,513W required -> 3,600W available (1,087W headroom)
Alternative startup path with reduced inrush.
1,131W required -> 3,600W available (2,469W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 1.0h
Device profile reference: up to 8h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Frigidaire Standard Window AC (FHWC084WB1) (2,010W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Midea U-Shaped Inverter (MAW08V1QWT) | 710W | 1,065W | Safe | ~1.0h | OEM Verified |
Show expert analysisTechnical: **Running load:** 710W (OEM rated cooling watts). **Surge:** ~1,065W (inverter ramp-up, no hard compressor start). **Voltage:** 115V AC, 8.78A AHAM rated. The variable-speed inverter compressor eliminates the traditional startup spike that trips smaller power stations. Power factor ~0.70 (710W real power vs 1,010 VA apparent). Field note: This is the most battery-friendly 8,000 BTU window AC on the market. The inverter eliminates the 3x surge spike that kills small generators. A power station rated 1,000W or above can handle this unit, though running draw at full cooling (710W) uses most of that headroom. Can I run the Midea U-Shaped inverter AC on a portable power station? Yes โ the inverter compressor draws up to 710W running with a ~1,065W soft startup, making it compatible with most power stations rated 1,000W or above. No hard compressor surge to worry about. | |||||
| Frigidaire Standard Window AC (FHWC084WB1) | 670W | 2,010W | Safe | ~1.1h | NEC Standard |
Show expert analysisTechnical: **Running load:** 670W (OEM rated). **Surge:** 2,010W at compressor startup (3x NEC standard). **Voltage:** 115V AC. Traditional on/off compressor cycles create hard inrush events every time the thermostat calls for cooling. Field note: This is the worst-case scenario for battery backup. The 2,010W compressor surge will trip any power station under 2,500W rated output. Budget window ACs are the #1 reason portable generators overload during heat waves. Why does my power station shut off when the Frigidaire AC compressor kicks in? The compressor startup surge hits ~2,010W โ roughly 3x the 670W running load. Your power station's inverter must handle this peak without tripping. You need at least 2,500W surge capacity. | |||||
| LG Dual Inverter Smart AC (LW8022IVSM) | 516W | 800W | Safe | ~1.4h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 516W (derived from 8,000 BTU at CEER 15.5). **Surge:** ~800W (dual inverter ramp-up). **Voltage:** 115V AC. The dual inverter compressor provides the highest efficiency in this class with the lowest startup demand. Field note: Premium efficiency and the lowest power demand in this class. Like the Midea, the dual inverter eliminates hard surge events. Ideal for smaller battery systems where every watt counts. Can I run the LG Dual Inverter window AC on battery power? Yes โ with only ~516W running and ~800W soft startup, this unit works with most power stations rated 1,000W or above. The dual inverter technology avoids the compressor surge that overloads smaller systems. | |||||
This unit ranks #7 of 23 compatible generators for this device by buffered margin (Overkill class).
23 of 33 generators are SAFE+TIGHT for Window AC (8,000 BTU).
Fit class uses buffered needs (running and surge) for this device.
Heat Wave Emergency
Select Your Model:
These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.
Free Tools
The 3600W surge capacity can support typical residential motor startup scenarios including refrigerator compressors, well pumps, and power tools with inductive loads. The 1024Wh capacity sustains the 1800W continuous rating for approximately 34 minutes at full draw. This configuration can handle brief high-demand events common in backup power and job site applications.
LFP chemistry provides stable electrochemical performance under load cycling. The 3600W surge rating indicates transient overcurrent capability designed for inductive startup events. Source: EcoFlow DELTA 3 Plus User Manual v1.0 (Output Specs Section) (manufacturer documentation). Users must verify that connected equipment falls within these published limits.
Keep your Window AC (8,000 BTU) running with solar โข MPPT: 11โ 60V โข Max: 1000W
Official 400W Panel
Adapter required: MC4 -> XT60i.
Smart Value 350W Panel
Adapter required: MC4 -> XT60i.
Smart Value 200W Panel
Adapter required: MC4 -> XT60i.
Yes. The EcoFlow DELTA 3 Plus provides 1800W running / 3600W surge. The Window AC (8,000 BTU) needs 888W / 2513W (including 25% buffer). That leaves 912W of running headroom and 1087W of surge margin.
Approximately 1.0 hours, based on the Window AC (8,000 BTU)'s 710W draw and the DELTA 3 Plus's 1024Wh capacity (70% usable after real-world losses).
With 430W allocated to the Window AC (8,000 BTU), the DELTA 3 Plus still has ~300W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your DELTA 3 Plus, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Window AC (8,000 BTU)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Midea MAW08V1QWT (710W OEM). Surge worst case = Frigidaire FHWC084WB1 (2,010W NEC 3x).
EcoFlow DELTA 3 Plus User Manual