Voltage Gate
PASSDevice output type must match generator output.
240V required -> 120V/240V available
3 of 3 models are compatible with this generator.
Jump to model-specific results โSame decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
240V required -> 120V/240V available
Continuous draw with safety buffer applied.
5,263W to 6,161W required -> 6,000W available (737W headroom on lighter models)
Startup peak with safety buffer applied.
5,263W to 6,161W required -> 12,000W available (5,839W to 6,737W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 0.8h
Device profile reference: up to 1h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: GE GTD38EASWWS (5,600W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Samsung DVE45T3200W | 5,300W | 5,300W | Safe | ~0.8h | OEM Manual |
Show expert analysisTechnical: **Running load:** 5300 W. **Surge:** 5300 W. Requires 240V split-phase. No additional inrush current observed beyond steady-state draw. Your power station must sustain 5300 W continuous output at 240V. Field note: Verify your power station's 240V receptacle is rated for sustained 5300 W loads. Undersized outlets or inverters will trip under this continuous draw. Can I run this dryer on a portable power station? Only if your power source provides 240V split-phase output and can supply 5300W continuous and 5300W surge. Most consumer units lack this capacity. | |||||
| GE GTD38EASWWS | 5,600W | 5,600W | Tight | ~0.8h | OEM Manual |
Show expert analysisTechnical: **Running load:** 5600 W continuous at 240V. **Surge:** 5600 W (no motor spike observed). Requires split-phase 240V output. Most portable power stations provide 120V only. Field note: Confirm your power station supports split-phase 240V before attempting connection. Single 120V outlets cannot supply this appliance. Can I run this dryer on a portable power station? Only if your power source provides 240V split-phase output and can supply 5600W continuous and 5600W surge. Capacity must exceed 5600 Wh for one full cycle. | |||||
| LG DLEX4000W | 4,784W | 4,784W | Safe | ~0.9h | OEM Manual |
Show expert analysisTechnical: **Running load:** 4784W at 240V split-phase. **Surge:** 4784W (resistive heating element, no motor surge). Requires a power station capable of continuous 240V output at this wattage. Field note: Verify your power station can sustain 4784W continuously on 240V. Many portable units lack the required voltage configuration or sustained wattage capacity. Can I run this dryer on a portable power station? Only if your power source provides 240V split-phase output and can supply 4784W continuous and 4784W surge. | |||||
This unit ranks #2 of 3 compatible generators for this device by buffered margin (Balanced class).
3 of 33 generators are SAFE+TIGHT for Electric Clothes Dryer.
Fit class uses buffered needs (running and surge) for this device.
Clothes Drying Cycle
Select Your Model:
This device typically needs 240V split-phase or a hardwired connection. Most portable stations are 120V-only. Verify the plug type and voltage on the device label/manual before purchase.
Free Tools
With 12000 watts of surge capacity, this system can handle typical startup loads for central air compressors, well pumps, and other motor-driven equipment common in residential settings. The 6000-watt continuous rating supports sustained operation of multiple high-draw appliances simultaneously. The 6144 Wh capacity provides meaningful runtime for essential circuits during grid outages.
This unit uses lithium iron phosphate (LFP) chemistry, known for stable thermal behavior in stationary storage applications. The system is designed with internal protections typical of grid-tied and off-grid battery platforms. Source: EcoFlow DELTA Pro Ultra User Manual (manufacturer documentation).
Keep your Electric Clothes Dryer running with solar โข MPPT: 80โ 450V โข Max: 5600W
Official 400W Panel
Smart Value 400W Panel
Smart Value 350W Panel
It depends on the model. 3 of 3 Electric Clothes Dryer models are compatible with the EcoFlow Delta Pro Ultra. See the model-specific results table for exact verdicts per model.
It depends on the model. Compatible models run approximately 0.8โ0.9 hours on the Delta Pro Ultra. 0 of 3 models are not compatible. See the model-specific results for details.
Efficiency Hack: Large appliances like the Electric Clothes Dryer cycle on and off. To maximize the 0.8 hours of runtime, try to minimize how often you open the device or introduce heat loads.
Compare all 33 generators for the Electric Clothes Dryer
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = GE GTD38EASWWS (5600W). Surge = running (resistive heating element โ no motor inrush).
EcoFlow DELTA Pro Ultra User Manual
Similar-output alternatives you can compare side by side.