Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
This pairing clears the safety headroom. Required ~888W running and 2513W surge; the Yeti 1500X is rated 2000W / 3500W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
888W required -> 2,000W available (1,112W headroom)
Startup peak with safety buffer applied.
2,513W required -> 3,500W available (987W headroom)
Alternative startup path with reduced inrush.
1,131W required -> 3,500W available (2,369W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 1.5h
Device profile reference: up to 8h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Frigidaire Standard Window AC (FHWC084WB1) (2,010W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Midea U-Shaped Inverter (MAW08V1QWT) | 710W | 1,065W | Safe | ~1.5h | OEM Verified |
Show expert analysisTechnical: **Running load:** 710W (OEM rated cooling watts). **Surge:** ~1,065W (inverter ramp-up, no hard compressor start). **Voltage:** 115V AC, 8.78A AHAM rated. The variable-speed inverter compressor eliminates the traditional startup spike that trips smaller power stations. Power factor ~0.70 (710W real power vs 1,010 VA apparent). Field note: This is the most battery-friendly 8,000 BTU window AC on the market. The inverter eliminates the 3x surge spike that kills small generators. A power station rated 1,000W or above can handle this unit, though running draw at full cooling (710W) uses most of that headroom. Can I run the Midea U-Shaped inverter AC on a portable power station? Yes โ the inverter compressor draws up to 710W running with a ~1,065W soft startup, making it compatible with most power stations rated 1,000W or above. No hard compressor surge to worry about. | |||||
| Frigidaire Standard Window AC (FHWC084WB1) | 670W | 2,010W | Safe | ~1.6h | NEC Standard |
Show expert analysisTechnical: **Running load:** 670W (OEM rated). **Surge:** 2,010W at compressor startup (3x NEC standard). **Voltage:** 115V AC. Traditional on/off compressor cycles create hard inrush events every time the thermostat calls for cooling. Field note: This is the worst-case scenario for battery backup. The 2,010W compressor surge will trip any power station under 2,500W rated output. Budget window ACs are the #1 reason portable generators overload during heat waves. Why does my power station shut off when the Frigidaire AC compressor kicks in? The compressor startup surge hits ~2,010W โ roughly 3x the 670W running load. Your power station's inverter must handle this peak without tripping. You need at least 2,500W surge capacity. | |||||
| LG Dual Inverter Smart AC (LW8022IVSM) | 516W | 800W | Safe | ~2.1h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 516W (derived from 8,000 BTU at CEER 15.5). **Surge:** ~800W (dual inverter ramp-up). **Voltage:** 115V AC. The dual inverter compressor provides the highest efficiency in this class with the lowest startup demand. Field note: Premium efficiency and the lowest power demand in this class. Like the Midea, the dual inverter eliminates hard surge events. Ideal for smaller battery systems where every watt counts. Can I run the LG Dual Inverter window AC on battery power? Yes โ with only ~516W running and ~800W soft startup, this unit works with most power stations rated 1,000W or above. The dual inverter technology avoids the compressor surge that overloads smaller systems. | |||||
This unit ranks #8 of 23 compatible generators for this device by buffered margin (Overkill class).
23 of 33 generators are SAFE+TIGHT for Window AC (8,000 BTU).
Fit class uses buffered needs (running and surge) for this device.
Heat Wave Emergency
Select Your Model:
These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.
Keep your Window AC (8,000 BTU) running with solar โข MPPT: 14โ 50V โข Max: 600W
Official 200W Panel
Adapter required: Goal Zero proprietary -> Anderson adapter required.
Smart Value 400W Panel
Adapter required: MC4 -> Anderson.
Smart Value 220W Panel
Adapter required: MC4 -> Anderson.
Yes. The Goal Zero Yeti 1500X provides 2000W running / 3500W surge. The Window AC (8,000 BTU) needs 888W / 2513W (including 25% buffer). That leaves 1112W of running headroom and 987W of surge margin.
Approximately 1.5 hours, based on the Window AC (8,000 BTU)'s 710W draw and the Yeti 1500X's 1516Wh capacity (70% usable after real-world losses).
With 385W allocated to the Window AC (8,000 BTU), the Yeti 1500X still has ~505W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your Yeti 1500X, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Window AC (8,000 BTU)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Midea MAW08V1QWT (710W OEM). Surge worst case = Frigidaire FHWC084WB1 (2,010W NEC 3x).
Goal Zero Yeti 1500X User Guide (147-100A)
Similar-output alternatives you can compare side by side.