Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
Yes - Explorer 1000 v2 has enough running and surge power for the Portable Ice Maker (Countertop). Target ~450W running / 1350W surge; the generator provides 1500W / 3000W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
450W required -> 1,500W available (1,050W headroom)
Startup peak with safety buffer applied.
1,350W required -> 3,000W available (1,650W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 2.1h
Device profile reference: up to 4h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: GE Profile Opal 2.0 (XPIO13SCSS) โ Nugget (1,080W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| GE Profile Opal 2.0 (XPIO13SCSS) โ Nugget | 360W | 1,080W | Safe | ~2.1h | OEM Verified |
Show expert analysisTechnical: The Opal 2.0 is the highest-draw variant in this set at 360W. Unlike basic bullet ice makers, nugget models use both a compressor and an auger to crush and form chewable ice, pushing power demand well above the 100โ120W typical of bullet units. Field note: At 360W this is not the lightweight camping load many expect. Verify your station can sustain it before hauling it to a tailgate โ a 500W station works, but leaves little headroom for anything else. Can a portable power station run a countertop ice maker? Yes โ the worst-case countertop ice maker in our set draws 360W running with an estimated 1080W startup surge. Any station rated above that threshold handles even the most power-hungry nugget models. Simpler bullet-style makers draw far less. Startup surge is modest (3x running) and rarely the bottleneck โ battery capacity determines session length, not whether you can start the machine. | |||||
| Frigidaire EFIC189-Silver โ Bullet | 105W | 315W | Safe | ~7.1h | OEM Manual |
Show expert analysisTechnical: A basic bullet ice maker drawing only 105W. The small hermetic compressor produces minimal startup inrush โ estimated at 315W, well within reach of even the smallest portable power stations. Field note: At 105W this pairs with virtually any power station in the catalog. The real camping question is runtime: a 300Wh station gives roughly 2 hours of active ice production before needing a recharge. Can a portable power station run a countertop ice maker? Yes โ the worst-case countertop ice maker in our set draws 360W running with an estimated 1080W startup surge. Any station rated above that threshold handles even the most power-hungry nugget models. Simpler bullet-style makers draw far less. Startup surge is modest (3x running) and rarely the bottleneck โ battery capacity determines session length, not whether you can start the machine. | |||||
| Igloo IGLICEB26HNSS โ Bullet | 120W | 360W | Safe | ~6.2h | OEM Manual |
Show expert analysisTechnical: A 120W bullet ice maker with a carry handle designed for portability. Draws 2A at 120V with a small hermetic R134a compressor producing minimal startup inrush. Field note: The carry handle and light weight make this the most camping-friendly option in the set. Pair it with a mid-range station (500Wh+) for a full afternoon of ice at a campsite. Can a portable power station run a countertop ice maker? Yes โ the worst-case countertop ice maker in our set draws 360W running with an estimated 1080W startup surge. Any station rated above that threshold handles even the most power-hungry nugget models. Simpler bullet-style makers draw far less. Startup surge is modest (3x running) and rarely the bottleneck โ battery capacity determines session length, not whether you can start the machine. | |||||
This unit ranks #8 of 27 compatible generators for this device by buffered margin (Overkill class).
27 of 33 generators are SAFE+TIGHT for Portable Ice Maker (Countertop).
Fit class uses buffered needs (running and surge) for this device.
Outdoor Ice Making / Tailgating
Select Your Model:
Free Tools
This unit can handle typical compressor-based loads like refrigerators and window AC units where startup surge falls within the 3000W envelope. The 1070Wh capacity supports moderate runtime on continuous loads under 1500W. It can start most residential sump pumps and small well pumps where inrush demand does not exceed the rated surge threshold.
LFP chemistry provides a stable platform for managing high-current transients during motor startup events. The 3000W surge rating allows the unit to absorb brief inrush currents without shutdown, though users must verify compatibility with specific appliances. Source: Jackery Explorer 1000 v2 User Manual (Sept 2024) (manufacturer documentation).
Keep your Portable Ice Maker (Countertop) running with solar โข MPPT: 16โ 60V โข Max: 400W
Official 200W Panel
Smart Value 200W Panel
Adapter required: MC4 -> DC8020.
Smart Value 200W Panel
Adapter required: MC4 -> DC8020.
Yes. The Jackery Explorer 1000 v2 provides 1500W running / 3000W surge. The Portable Ice Maker (Countertop) needs 450W / 1350W (including 25% buffer). That leaves 1050W of running headroom and 1650W of surge margin.
Approximately 2.1 hours, based on the Portable Ice Maker (Countertop)'s 360W draw and the Explorer 1000 v2's 1070Wh capacity (70% usable after real-world losses).
With 835W allocated to the Portable Ice Maker (Countertop), the Explorer 1000 v2 still has ~5W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your Explorer 1000 v2, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Portable Ice Maker (Countertop)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = GE Profile Opal 2.0 XPIO13SCSS (360W OEM from geappliances.com spec page). Surge worst case = GE Profile Opal 2.0 (1080W, 3x compressor startup estimate โ no OEM LRA published for any variant).
Jackery Explorer 1000 v2 User Manual (Sept 2024)
Similar-output alternatives you can compare side by side.