Capacity
AC180: +384 Wh (+50.0%).
This comparison targets buyers choosing between two Bluetti LFP stations that share the same solar panel compatibility (19 panels, 500W max input) but sit in different weight and output classes. The AC180 delivers 1800W of running power with 2700W surge and a 1152 Wh battery, powering 39 out of 53 devices tested.
The AC70 runs at 1000W with a 2000W surge and 768 Wh of capacity, covering 24 of those same 53 devices. That gap in device coverage is significant: every device the AC70 can handle, the AC180 handles too, but 15 additional devices only run on the larger unit.
The AC180 also adds UPS functionality with a 20ms switchover and offers 3500 charge cycles versus 3000. The tradeoff is weight: at 36.2 lbs the AC180 is nearly 14 lbs heavier than the 22.5 lb AC70, which matters for camp trips and trunk space.
Overall Winner
AC180
Powers 39 of 53 tested devices vs 24 for AC70
AC180 wins overall, but the best pick depends on your use case.
Absolute values shown. Bars are scaled within this comparison for readability.
Each metric is independent. Bar lengths are not comparable across different compare pages.
AC180: +384 Wh (+50.0%).
AC180: +800 W (+80.0%).
AC180: +700 W (+35.0%).
AC70: -13.7 lbs (37.8% lighter).
AC180: +500 cycles (+16.7%).
Out of 53 devices tested, 15 show a different result between these two stations.
Both can run: 24 · Differences: 28% (15/53) · Neither can run: 14
2-Slice Bread Toaster AC70: Running shortfall
Coffee Maker AC70: Running shortfall
Digital Air Fryer AC70: Running shortfall
Electric Skillet AC70: Running shortfall
Electric Stove (Single Burner) AC70: Running shortfall
Electric Water Kettle AC70: Running shortfall
Instant Pot (6 Qt) AC70: Running shortfall
Toaster Oven AC70: Running shortfall
Gas Furnace Fan (Blower) AC70: Running + surge shortfall
Space Heater (1,500W) AC70: Running shortfall
Window AC (8,000 BTU) AC70: Needs soft-start
Dishwasher AC70: Running shortfall
Washing Machine AC70: Running shortfall
EV Charger (Level 1, 120V) AC70: Running shortfall
Professional Hair Dryer AC70: Running shortfall
These devices have startup surges that exceed both stations.
Microwave Oven (1000W)
Central AC (3-Ton)
Dehumidifier (70 Pint)
Portable AC (12,000 BTU)
Electric Clothes Dryer
Sump Pump (1/2 HP)
Electric Water Heater (50 Gal)
Well Pump (1 HP)
RV Rooftop AC (13,500 BTU)
Circular Saw (Corded)
Corded Drill / Hammer Drill
Electric Chainsaw (14-inch)
Pancake Air Compressor (6-Gallon)
Shop Vac (Wet/Dry, 5-6 HP Peak)
| Spec | AC180 | AC70 |
|---|---|---|
| Capacity | 1,152 Wh ✓ | 768 Wh |
| Running Power | 1,800 W ✓ | 1,000 W |
| Surge Power | 2,700 W ✓ | 2,000 W |
| Weight | 36.2 lbs (16.4 kg) | 22.5 lbs (10.2 kg) ✓ |
| Energy Density | 70.2 Wh/kg | 75.3 Wh/kg ✓ |
| Portability Tier | portable | portable |
| Chemistry | LFP | LFP |
| Cycle Life | 3,500 ✓ | 3,000 |
| Expandable | No | No |
| UPS | Yes (20 ms) | No |
| AC Voltage | 120V | 120V |
Best-case charging profile using compatible solar panels.
MPPT: 12-60V
MPPT: 12-58V
Charge speed comparison
Longer bar = faster charge (inverted scale)
All tested devices grouped by category. Click a category to expand.
| Device | AC180 | Runtime | AC70 | Runtime |
|---|---|---|---|---|
| Full-Size Freezer (15-17 Cu. Ft.) | Safe | 5h | Safe | 3.4h |
| Sump Pump (1/2 HP) | Soft Start | 0.7h | Fail | N/A |
| Device | AC180 | Runtime | AC70 | Runtime |
|---|---|---|---|---|
| Box Fan (20-inch) | Safe | 9.7h | Safe | 6.5h |
| Central AC (3-Ton) | Voltage Fail | N/A | Voltage Fail | N/A |
| Dehumidifier (70 Pint) | Soft Start | 0.9h | Fail | N/A |
| Gas Furnace Fan (Blower) | Tight | 0.8h | Fail | N/A |
| Portable AC (12,000 BTU) | Soft Start | 0.6h | Fail | N/A |
| Space Heater (1,500W) | Safe | 0.5h | Fail | N/A |
| Window AC (8,000 BTU) | Safe | 1.1h | Soft Start | 0.8h |
| Device | AC180 | Runtime | AC70 | Runtime |
|---|---|---|---|---|
| Electric Water Heater (50 Gal) | Voltage Fail | N/A | Voltage Fail | N/A |
| Garage Door Opener (Residential) | Safe | 4.5h | Safe | 3h |
| Well Pump (1 HP) | Voltage Fail | N/A | Voltage Fail | N/A |
| Device | AC180 | Runtime | AC70 | Runtime |
|---|---|---|---|---|
| 2-Slice Bread Toaster | Safe | 0.5h | Fail | N/A |
| Coffee Maker | Safe | 0.5h | Fail | N/A |
| Digital Air Fryer | Tight | 0.5h | Fail | N/A |
| Electric Skillet | Safe | 0.5h | Fail | N/A |
| Electric Stove (Single Burner) | Tight | 0.4h | Fail | N/A |
| Electric Water Kettle | Safe | 0.5h | Fail | N/A |
| Instant Pot (6 Qt) | Safe | 0.6h | Fail | N/A |
| Microwave Oven (1000W) | Fail | N/A | Fail | N/A |
| Rice Cooker | Safe | 0.9h | Tight | 0.6h |
| Slow Cooker | Safe | 2.7h | Safe | 1.8h |
| Toaster Oven | Tight | 0.4h | Fail | N/A |
| Device | AC180 | Runtime | AC70 | Runtime |
|---|---|---|---|---|
| Dishwasher | Tight | 0.4h | Fail | N/A |
| Electric Clothes Dryer | Voltage Fail | N/A | Voltage Fail | N/A |
| French Door Refrigerator | Safe | 3.9h | Safe | 2.6h |
| Washing Machine | Safe | 0.6h | Fail | N/A |
As an Amazon Associate, we earn from qualifying purchases. Our methodology
Buyers who need reliable home backup power, UPS protection, or the ability to run higher-draw appliances should pick the AC180. The AC70 makes sense for lighter-duty use where portability is the priority and 1000W of output covers your gear, and its faster 2.7-hour solar charge time is a genuine advantage over the AC180's 4.1 hours. Overall, the AC180 wins this matchup with a score of 73.5 versus 46.5, earning the recommendation for most buyers who can handle the extra weight.
AC180 is the stronger overall choice in this matchup based on weighted compatibility across 53 tested devices.
AC180 has higher battery capacity (1,152 Wh), which generally supports longer runtime on the same load.
AC70 has the faster best-case solar recharge profile in our panel compatibility test set.
AC70 is lighter at 22.5 lbs vs 36.2 lbs. AC70 is rated portable for portability.
AC180 powers 39 of 53 tested devices, compared to 24 for AC70.
Only AC180 has UPS (uninterruptible power supply) mode with a 20ms switchover time, which keeps connected devices running during a power outage without interruption.